Literature DB >> 2567759

Nosocomial Legionella micdadei pneumonia: 10 years experience and a case-control study.

B N Doebbeling1, M A Ishak, B H Wade, M A Pasquale, R E Gerszten, D H Gröschel, R J Kadner, R P Wenzel.   

Abstract

Sixteen patients with nosocomial Legionella micdadei pneumonia, diagnosed between 1977 and 1988, were studied retrospectively to define clinical and epidemiological characteristics of the disease. Also, a case-control study was performed comparing the five patients with L. micdadei pneumonia during a cluster of cases in 1982, with uninfected patients with the same underlying diagnoses. No significant differences were noted in the case-control study with regard to age, presence of leucopenia, intensity or duration of immunosuppressive therapy, bed location, duration of hospital stay, frequency of transplant rejection or overall mortality. Legionella micdadei isolates from a sink on the renal transport ward, from hot water storage tanks, and one clinical isolate had identical cellular fatty acid composition. Extensive sampling of other potential sources failed to yield the organism. This indirect evidence suggests potable water as the source of infection.

Entities:  

Mesh:

Year:  1989        PMID: 2567759     DOI: 10.1016/0195-6701(89)90010-8

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  7 in total

Review 1.  Diagnostic Accuracy of PCR Alone and Compared to Urinary Antigen Testing for Detection of Legionella spp.: a Systematic Review.

Authors:  Tomer Avni; Amir Bieber; Hefziba Green; Tali Steinmetz; Leonard Leibovici; Mical Paul
Journal:  J Clin Microbiol       Date:  2015-12-09       Impact factor: 5.948

Review 2.  Legionella micdadei prosthetic valve endocarditis.

Authors:  D Park; A Pugliese; B A Cunha
Journal:  Infection       Date:  1994 May-Jun       Impact factor: 3.553

3.  Pityriasis rosea Gibert: detection of Legionella micdadei antibodies in patients.

Authors:  I Gjenero-Margan; R Vidovic; V Drazenovic
Journal:  Eur J Epidemiol       Date:  1995-08       Impact factor: 8.082

Review 4.  Engineering infection control through facility design.

Authors:  G A Noskin; L R Peterson
Journal:  Emerg Infect Dis       Date:  2001 Mar-Apr       Impact factor: 6.883

5.  Simultaneous detection of Legionella species and L. anisa, L. bozemanii, L. longbeachae and L. micdadei using conserved primers and multiple probes in a multiplex real-time PCR assay.

Authors:  Kristen E Cross; Jeffrey W Mercante; Alvaro J Benitez; Ellen W Brown; Maureen H Diaz; Jonas M Winchell
Journal:  Diagn Microbiol Infect Dis       Date:  2016-04-02       Impact factor: 2.803

6.  Comparison of BCYEα+AB agar and MWY agar for detection and enumeration of Legionella spp. in hospital water samples.

Authors:  Savina Ditommaso; Monica Giacomuzzi; Gabriele Memoli; Jacopo Garlasco; Carla M Zotti
Journal:  BMC Microbiol       Date:  2021-02-16       Impact factor: 3.605

Review 7.  Legionellosis Caused by Non-Legionella pneumophila Species, with a Focus on Legionella longbeachae.

Authors:  Stephen T Chambers; Sandy Slow; Amy Scott-Thomas; David R Murdoch
Journal:  Microorganisms       Date:  2021-01-31