Literature DB >> 25676365

Comparability of modern recording devices for speech analysis: smartphone, landline, laptop, and hard disc recorder.

Adam P Vogel1, Kristin M Rosen, Angela T Morgan, Sheena Reilly.   

Abstract

BACKGROUND: Large-scale multi-site experimental and clinical speech protocols require high-fidelity, easy-to-use speech recording technologies. However, little is known about the reliability and comparability of affordable, portable and commonly used technologies with traditional well-validated devices (e.g., a hard disc recorder with a high-quality microphone).
OBJECTIVE: To examine the comparability of speech and voice samples acquired from protocols involving high- and low-quality devices.
METHODS: Speech samples were acquired simultaneously from 15 healthy adults using four devices and analyzed acoustically for measures of timing and voice quality. For the purpose of making initial comparisons, methods were deemed comparable if the resultant acoustic data yielded root mean squared error values ≤10% and statistically significant Spearman's correlation coefficients.
RESULTS: The data suggest that there is significant and widespread variability in the quality and reliability between different acquisition methods for voice and speech recording. Not one method provided statistically similar data to the protocol using the benchmark device (i.e., a high-quality recorder coupled with a condenser microphone). Acoustic analysis cannot be assumed to be comparable if different recording methods are used to record speech.
CONCLUSIONS: Findings have implications for researchers and clinicians hoping to make comparisons between labs or, where lower-quality devices are suggested, to offer equal fidelity.
© 2015 S. Karger AG, Basel.

Mesh:

Year:  2015        PMID: 25676365     DOI: 10.1159/000368227

Source DB:  PubMed          Journal:  Folia Phoniatr Logop        ISSN: 1021-7762            Impact factor:   0.849


  3 in total

1.  An iOS-based VoiceScreen application: feasibility for use in clinical settings-a pilot study.

Authors:  Virgilijus Uloza; Nora Ulozaite-Staniene; Tadas Petrauskas
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-07-29       Impact factor: 3.236

Review 2.  Static measurements of vowel formant frequencies and bandwidths: A review.

Authors:  Raymond D Kent; Houri K Vorperian
Journal:  J Commun Disord       Date:  2018-06-01       Impact factor: 2.288

3.  Comparing acoustic analyses of speech data collected remotely.

Authors:  Cong Zhang; Kathleen Jepson; Georg Lohfink; Amalia Arvaniti
Journal:  J Acoust Soc Am       Date:  2021-06       Impact factor: 1.840

  3 in total