Literature DB >> 25676054

Trans-pulmonary echocardiography as a guide for device closure of patent ductus arteriosus.

Yoshiyuki Kudo1, Kenji Suda1, Hironaga Yoshimoto1, Yozo Teramachi2, Shintaro Kishimoto1, Motofumi Iemura2, Toyojiro Matsuishi1.   

Abstract

OBJECTIVES: The aim of this study was to develop trans-pulmonary echocardiography (TPE) to guide device closure of patent ductus arteriosus (DC-PDA).
BACKGROUND: Aortography requires a large amount of contrast yet may give us an inadequate image to evaluate anatomy or residual shunt in patients with large PDA or dilated vessels and is precluded in patients with renal dysfunction. Practically, there is no imaging modality to monitor the entire procedure except for trans-esophageal echocardiography that requires general anesthesia.
METHODS: Subjects were seven patients with ages ranged from 6- to 77-years old and body weight > 15 kg. The size of the PDA ranged from 1.8 to 6.3 mm with pulmonary to systemic flow ratios from 1.2 to 2.2. During DC-PDA using Ampaltzer Duct Occluder or coil, an intra-cardiac echocardiographic (ICE) catheter was advanced into pulmonary arteries and standard views were developed to guide DC-PDA.
RESULTS: We have developed two standard views; the main pulmonary artery view (MPA view) and the left pulmonary artery view (LPA view). The MPA view provided aortic short axis view equivalent to that seen by trans-thoracic echocardiography in children. The LPA view, obtained by the echo probe in the LPA and turned it up upside down, provided long axis view of the PDA allowing more precise anatomical evaluation. TPE allowed us to monitor the entire procedure and determine residual shunts.
CONCLUSIONS: TPE in the MPA and LPA view can be an effective guide for DC-PDA. This report leads to new application of this imaging device.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  Amplatzer duct occluder; aortography; intracardiac echocardiography; monitoring tool; residual shunt

Mesh:

Year:  2015        PMID: 25676054     DOI: 10.1002/ccd.25879

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

Review 1.  Intracardiac Echocardiography for Structural Heart and Electrophysiological Interventions.

Authors:  Craig Basman; Yuvrajsinh J Parmar; Itzhak Kronzon
Journal:  Curr Cardiol Rep       Date:  2017-09-06       Impact factor: 2.931

2.  Intracardiac Echocardiography as a Guide for Transcatheter Closure of Patent Ductus Arteriosus.

Authors:  Hironaga Yoshimoto; Maeda Yasuto; Tadashi Inoue; Yoshiyuki Kagiyama; Yozo Teramachi; Ryuta Takase; Yusuke Koteda; Yoshihiro Fukumoto; Motofumi Iemura; Kenji Suda
Journal:  J Interv Cardiol       Date:  2020-07-30       Impact factor: 2.279

3.  Ductal closure in infants under 6 kg including premature infants using AmplatzerTM duct occluder type two additional sizes: a single-centre experience in South Africa.

Authors:  Lungile Pepeta; Adele Greyling; Mahlubandile Fintan Nxele; Zongezile Makrexeni; Samkelo Jiyana
Journal:  Cardiovasc J Afr       Date:  2019-08-30       Impact factor: 1.167

4.  Clinical study of stand-alone transthoracic echocardiography-guided percutaneous occlusion of patent ductus arteriosus.

Authors:  Hua Cao; Qiang Chen; Gui Can Zhang; Liang Wan Chen; Fan Xu; Jia-Xin Zhang
Journal:  Anatol J Cardiol       Date:  2018-07       Impact factor: 1.596

  4 in total