Literature DB >> 25675679

Comparative study between the Phramongkutklao's diabetic blenderized diets and commercial diabetic diets on glycemic variability in continuous tube fed patients with type 2 diabetes.

Teeranun Tiyapanjanit, Apussanee Boonyavarakul.   

Abstract

BACKGROUND: Rapid glucose fluctuations over daily period play an important role on diabetic complications.
OBJECTIVE: To compare glycemic variability, mean plasma glucose, number ofcapillary blood glucose tests, and cost between the Phramongkutklao's diabetic formula and commercial diabetic formula in continuous tube fed patients with stable condition in type 2 diabetes. MATERIAL AND
METHOD: A cross-over design study was performed between October 2010 and February 2011 in the medical department in Phramongkutklao Hospital. The researchers enrolled type 2 diabetic patients with stable condition who were on continuous tube fed. Seventy-two-hour continuous subcutaneous glucose monitoring was performed in all patients. Comparison ofmean amplitude ofglycemic excursions (MAGE), mean plasma glucose, cost, and number of capillary blood glucose tests were analyzed by using non-parametric Wilcoxon signed-rank test. Significance was defined as p<0.05.
Results: Ten subjects were included in the present study. The Phramongkutklao's Diabetic Formula resulted in significantly lower mean plasma glucose (122±26.25 vs. 144.68±36.91 mg/dL, p = 0.022), cost (550.1±33.57 vs. 797.81±42.29 baht, p = 0.004), and number of capillary blood glucose tests (5±0.94 vs. 5.3±0.82 times, p = 0.083) when compared with commercial diabetic formula, but no significant difference in MAGE level (5.86±2.78 vs. 7.71±4.34 mg/dL, p = 0.333).
CONCLUSION: The Phramongkutklao's diabetic formula has significantly lower mean plasma glucose, less number of capillary blood glucose tests, and is less expensive than commercial diabetic formula. The glucose variability (MAGE) of the Phramongkutklao diabetic formula has also less than commercial diabetic formula, but does not reach statistical significance. The level ofplasma glucose was lower than 180 mg/dL in both formulas.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25675679

Source DB:  PubMed          Journal:  J Med Assoc Thai        ISSN: 0125-2208


  2 in total

1.  A Survey of Home Enteral Nutrition Practices and Reimbursement in the Asia Pacific Region.

Authors:  Alvin Wong; Merrilyn D Banks; Judith D Bauer
Journal:  Nutrients       Date:  2018-02-14       Impact factor: 5.717

2.  An Evaluation of the Nutritional Value and Physical Properties of Blenderised Enteral Nutrition Formula: A Systematic Review and Meta-Analysis.

Authors:  Omorogieva Ojo; Amanda Rodrigues Amorim Adegboye; Osarhumwese Osaretin Ojo; Xiaohua Wang; Joanne Brooke
Journal:  Nutrients       Date:  2020-06-20       Impact factor: 5.717

  2 in total