Biomechanical evaluation of syndesmotic screw design via finite element analysis and Taguchi's method.

Mehmet Serhan Er, Ozgur Verim, Mehmet Eroglu, Levent Altinel, Bariş Gokce, Suleyman Tasgetiren.   

Abstract

BACKGROUND: Screw fixation of syndesmotic injuries facilitates ligament healing and restoration of ankle stability, but failure of the screw might threaten the success of the treatment. Screw design parameters, such as outer diameter, inner diameter, thread pitch, leading edge radius, trailing edge radius, leading edge angle, and trailing edge angle, might have effects on the stresses that occur in the screws. This is the first study, to our knowledge, to investigate which geometric screw parameters play key roles in stresses that occur in screws used for syndesmotic fixation.
METHODS: A three-dimensional finite element model of an ankle was reconstructed. Four different types of titanium screws—4.5-mm malleolar, 4-mm cancellous, 4-mm machine, and 3.5-mm cortical—were placed on this model. Physiologic load was applied to evaluate the stress in the screw. Then the contribution of each design factor to stress in the screws was analyzed systematically by Taguchi's robust design method.
RESULTS: The maximum equivalent ductile failure (von Mises equivalent stress) value was found in the 4-mm cancellous screw (402 MPa). Taguchi's analysis showed that the descending order of contribution of the design factors to stress emerging on the screw is inner diameter, leading edge angle, thread pitch, outer diameter, and trailing edge angle.
CONCLUSIONS: Stress that occurs in syndesmotic screws is closely related to their geometry and dimensions. According to the results, a 3.5-mm cortical screw with the ideal screw design regarding optimal parameters to resist against stresses in the syndesmosis seems more reasonable to choose in syndesmotic fixation.

Entities:  

Mesh:

Year:  2015        PMID: 25675221     DOI: 10.7547/8750-7315-105.1.14

Source DB:  PubMed          Journal:  J Am Podiatr Med Assoc        ISSN: 1930-8264


  3 in total

1.  Optimizing left anterior oblique (LAO) caudal imaging in coronary angiography using the Taguchi method: A phantom study with clinical verification.

Authors:  Lung-Fa Pan; Kuang Hua Chu; Hai-Feng Sher; Lung-Kwang Pan
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-31       Impact factor: 2.357

2.  Deformation of the Titanium Plate Stabilizing the Lateral Ankle Fracture Due to Its Overloading in Case of the Young, Obese Patient: Case Report Including the Biomechanical Analysis.

Authors:  Grzegorz Szczęsny; Mateusz Kopec; Tomasz Szolc; Zbigniew L Kowalewski; Paweł Małdyk
Journal:  Diagnostics (Basel)       Date:  2022-06-16

Review 3.  Bio-Functional Design, Application and Trends in Metallic Biomaterials.

Authors:  Ke Yang; Changchun Zhou; Hongsong Fan; Yujiang Fan; Qing Jiang; Ping Song; Hongyuan Fan; Yu Chen; Xingdong Zhang
Journal:  Int J Mol Sci       Date:  2017-12-22       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.