Literature DB >> 25675057

Digital subtraction angiography versus real-time fluoroscopy for detection of intravascular penetration prior to epidural steroid injections: meta-analysis of prospective studies.

Ognjen Visnjevac, Paul Kim, Sina Farid-Davari, Patrick Johnson, Nader Djalal Nader1.   

Abstract

BACKGROUND: Neurological injury is a rare but devastating complication of epidural steroid injections (ESIs) generally thought to arise from neurovascular compromise. The use of real-time fluoroscopy (RTF) with contrast media is the most common preventative measure taken to avoid intravascular penetration. In 2002, it was proposed that digital subtraction angiography (DSA) might be more useful than RTF. Since then, several prospective studies have advocated for its use.
OBJECTIVES: As DSA is not currently a "gold standard," a meta-analysis was performed to compare the efficacy of DSA versus RTF for detection of intravascular penetration during ESI. STUDY
DESIGN: Meta-analysis of prospective observational studies.
METHODS: A targeted Pubmed search was conducted, yielding 49 reports and 4 manuscripts, which were analyzed using Review Manager Software (Rev Man 5.2). Inclusion/exclusion criteria: peer-reviewed prospective reports comparing the sensitivity of DSA to RTF in the same individuals without change in needle position between comparative imaging. Pooled estimate of odds ratios with 95% confidence interval using a random effect model was applied.
RESULTS: There were a total of 188 intravascular events from 1,290 ESIs performed. RTF was able to detect 148 events with DSA detecting an additional 40 events missed by RTF. No major neurological complications were reported. DSA had a statistically significant favorable odds ratio over RTF for detection of intravascular penetration during ESI (OR = 1.32 [1.05 - 1.67]; P = 0.02). LIMITATIONS: Although the major methodological aspects of each study assessed in this meta-analysis were quite similar, there were small differences in needle gauge and the selection of secondary outcome measures. Despite attempts to minimize it, concern for operator bias also exists.
CONCLUSIONS: DSA had a 32% improvement (OR = 1.32) for detection of intravascular penetration with ESI when compared to RTF. Although this supports advocacy for use of DSA, it also suggests that there is a greater than 30% "missed-events" rate for detection of vascular penetration when using RTF for ESI, which does not correlate with the generally reported cumulative rates of complications (1%). This discrepancy suggests that factors other than vascular events also play a role in complications. Nonetheless, given the evidence, we advocate for the increased use of DSA over RTF for transformational ESIs.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25675057

Source DB:  PubMed          Journal:  Pain Physician        ISSN: 1533-3159            Impact factor:   4.965


  4 in total

Review 1.  Spine injections: the rationale for CT guidance.

Authors:  Sanja Bogdanovic; Reto Sutter; Veronika Zubler
Journal:  Skeletal Radiol       Date:  2022-09-23       Impact factor: 2.128

2.  Correlation Between Intravascular Injection Rate, Pain Intensity, and Degree of Cervical Neural Foraminal Stenosis During a Cervical Transforaminal Epidural Block.

Authors:  Jiseob Kim; Kilhyun Kim; MinKyu Lee; Saeyoung Kim
Journal:  J Pain Res       Date:  2021-09-24       Impact factor: 3.133

3.  Effect of needle type on intravascular injection in transforaminal epidural injection: a meta-analysis.

Authors:  Jae Yun Kim; Soo Nyoung Kim; Chulmin Park; Ho Young Lim; Jae Hun Kim
Journal:  Korean J Pain       Date:  2019-01-02

4.  Digital subtraction angiography vs. real-time fluoroscopy for detection of intravascular injection during transforaminal epidural block.

Authors:  Kibeom Park; Saeyoung Kim
Journal:  Yeungnam Univ J Med       Date:  2019-01-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.