[Measurement of response function of CdTe detector using diagnostic X-ray equipment and evaluation of Monte Carlo simulation code].

Hiroki Okino1, Hiroaki Hayashi, Kohei Nakagawa, Kazuki Takegami.   

Abstract

An X-ray spectrum measured with CdTe detector has to be corrected with response function, because the spectrum is composed of full energy peaks (FEP) and escape peaks (EP). Recently, various simulation codes were developed, and using them the response functions can be calculated easily. The aim of this study is to propose a new method for measuring the response function and to compare it with the calculated value by the Monte Carlo simulation code. In this study, characteristic X-rays were used for measuring the response function. These X-rays were produced by the irradiation of diagnostic X-rays with metallic atoms. In the measured spectrum, there was a background contamination, which was caused by the Compton scattering of the irradiated X-ray in the sample material. Therefore, we thought of a new experimental methodology to reduce this background. The experimentally derived spectrum was analyzed and then the ratios of EP divided by FEP (EP/FEP) were calculated to compare the simulated values. In this article, we showed the property of the measured response functions and the analysis accuracy of the EP/FEP, and we indicated that the values calculated by Monte Carlo simulation code could be evaluated by using our method.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25672443     DOI: 10.6009/jjrt.2014_JSRT_70.12.1381

Source DB:  PubMed          Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi        ISSN: 0369-4305


  3 in total

1.  Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Hiroki Okino; Natsumi Kimoto; Itsumi Maehata; Yuki Kanazawa; Tohru Okazaki; Takuya Hashizume; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2015-11-20

2.  Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms.

Authors:  Itsumi Maehata; Hiroaki Hayashi; Natsumi Kimoto; Kazuki Takegami; Hiroki Okino; Yuki Kanazawa; Masahide Tominaga
Journal:  Radiol Phys Technol       Date:  2016-03-18

3.  Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Hiroki Okino; Natsumi Kimoto; Itsumi Maehata; Yuki Kanazawa; Tohru Okazaki; Takuya Hashizume; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2016-06-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.