Alternative techniques to remove fractured instrument fragments from the apical third of root canals: report of two cases.

Manoel Brito-Júnior1, João Américo Normanha1, Carla Cristina Camilo1, André Luis Faria-e-Silva2, Paulo César Saquy1, Maria Ãngela Arêa Leão Ferraz3, Yara Teresinha Correa Silva-Sousa1.   

Abstract

This paper describes two cases of instrument fragment removal from the apical thirds of root canals using a customized extractor and a modified needle technique, respectively. In case 1, a customized extractor was manufactured to remove a bur fragment located in the apical root canal of a maxillary central incisor. The use of this extractor enabled successful and conservative removal of the instrument fragment. In case 2, a modified injection needle was used as a trepan to gain access around an instrument fragment located in the curved apical portion of the mesiobuccal canal of a mandibular molar. A segment of steel wire was inserted into the needle lumen to engage the metallic fragment, enabling its removal with counter-clockwise rotation and a simultaneous pull-out motion. Alternative and creative methods are useful for the management of intracanal metallic fragments during root canal treatment.

Mesh:

Year:  2015        PMID: 25672390     DOI: 10.1590/0103-6440201302446

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  2 in total

1.  Broken Instrument Removal from Mandibular First Molar with Conebeam Computed Tomography based Pre-operative Computer-assisted Simulation: A Case Report.

Authors:  Babita Pradhan; Yuan Gao; Yuan Gao; Tingwei Guo; Yangpei Cao; Jinzhi He
Journal:  JNMA J Nepal Med Assoc       Date:  2021-08-12       Impact factor: 0.556

2.  Removing Fractured Endodontic NiTi Instruments with a Tube Technique: Influence of Pre-Treatment with Various Agents on Adhesive Forces In Vitro.

Authors:  Sebastian Bürklein; David Donnermeyer; Michael Wefelmeier; Edgar Schäfer; Kent Urban
Journal:  Materials (Basel)       Date:  2019-12-30       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.