Literature DB >> 25665992

Assessment of root surfaces of apicected teeth: a scanning electron microscopy evaluation.

F Ayranci1, L B Ayranci, H Arslan, M M Omezli, M C Topcu.   

Abstract

OBJECTIVES: The aim of this study was to determine the apical surface characteristics and presence of dental cracks in single-rooted premolars, resected 3.0 mm from the root apex, using the Er: YAG laser, tungsten carbide bur, and diamond-coated tip, by scanning electron microscopy (SEM). EXPERIMENTAL
DESIGN: Thirty single-rooted premolar teeth were collected. The instrumented and obturated teeth were divided into three groups according to the root resection method (2.94 μm, 100 mj, 20-Hz Er: YAG laser, plain tapered fissure tungsten carbide bur at a low speed of 40,000 rpm, or a diamond-coated SG6D tip coupled to the handpiece of a conventional ultrasound device). The specimens were prepared for SEM and analyzed by the Kruskal-Wallis and Mann-Whitney statistical tests.
RESULTS: The SEM images showed that tungsten carbide burs produced significantly smoother resected root surfaces than the diamond-coated tip. There was no statistically significant difference between the Er: YAG and tungsten carbide bur groups. The analysis of scores obtained for the cut quality by the Kruskal-Wallis test revealed no significant differences among the groups. In our study, five teeth had no cracks after the apical resection. The mean number of cracks per tooth was 3.5 ± 1.780 (Er: YAG laser group), 2.5 ± 1.716 (tungsten carbide bur group), and 4.5 ± 2.593 (diamond-coated tip group).
CONCLUSIONS: Under the tested conditions smoother surfaces were observed in the groups treated with the tungsten carbide bur and Er: YAG laser when compared with the diamond-coated tips.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25665992     DOI: 10.4103/1119-3077.151041

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  2 in total

1.  Resistance to vertical root fracture of apicoected teeth using different devices during two root canal irrigation procedures.

Authors:  Ferhat Ayrancı; Leyla Benan Ayrancı; Alper Özdoğan; Serkan Özkan; Mutlunur Önder Peker; Mutan Hamdi Aras
Journal:  Lasers Med Sci       Date:  2018-04-26       Impact factor: 3.161

2.  Comparative evaluation of microleakage after root-end resection by erbium, chromium: Yttrium-scandium-gallium-garnet (Er, Cr:YSGG) laser and carbide bur with or without placement of mineral trioxide aggregate: An in vitro study.

Authors:  Shabnam Negi; Hari Das Adhikari; Dibyendu Mazumder; R Deirimika Lakiang; Sarita Bhardwaj
Journal:  J Conserv Dent       Date:  2019 Jul-Aug
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.