Literature DB >> 25664701

Radiographic evaluation of immediately loaded implants supporting 2-3 units fixed bridges in the posterior maxilla: a 3-year follow-up prospective randomized controlled multicenter clinical study.

Gianfranco Cesaretti1, Daniele Botticelli1,2, Antonio Renzi2, Marcello Rossi3, Riccardo Rossi3, Niklaus P Lang4,5.   

Abstract

OBJECTIVE: To compare the survival rate and alveolar bone levels at implants installed in healed sites and functionally loaded within 1 h from installation or after 3 months.
MATERIAL AND METHODS: A total of 30 patients (17 male and 13 female) were recruited and 71 implants with a SLA(®) surface, 4.1 mm in diameter and 8-12 mm long, were installed in a fully healed alveolar ridge, 36 as test and 35 as control implants. The test implants were immediately loaded with a temporary reconstruction in proper occlusion, while the randomly selected control sites received the final reconstruction after 3 months. Radiographic bone levels were determined after implant installation, prosthesis delivery, and at annual intervals thereafter.
RESULTS: One patient of the control and one patient of the test were excluded from evaluation. No further losses of implants or patients were seen up to the 3-year follow-up. Hence, data from 28 patients were accounted for. A total of 37 and 36 metal-ceramic crowns were provided at the test and control sites, respectively. No biological and technical complications were observed during the 3-year follow-up. Bone levels at the time of implant installation were at 1.6 ± 0.8 and 1.7 ± 0.9 mm from the implant shoulder at the test and control sites, respectively. At prosthesis delivery, the bone levels were located at 2.4 ± 0.7 mm at the control sites 3 months after implant placement. After 1 year of function, similar bone levels were observed at both sites, displaying 2.4 ± 1.0 and 2.5 ± 0.8 mm at the test and control sites, respectively. No differences were found in the subsequent observation periods.
CONCLUSION: Survival rates and radiographic bone levels after 1, 2, and 3 years of observation did not differ between conventionally installed implants loaded immediately or delayed (after 3 months). Moreover, insertion torque values did not affect osseointegration.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  SLA surface; dental implants; immediate loading; prospective randomized study

Mesh:

Year:  2015        PMID: 25664701     DOI: 10.1111/clr.12565

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  1 in total

1.  Bone healing at non-submerged implants installed with different insertion torques: a split-mouth histomorphometric randomized controlled trial.

Authors:  Yoshiyuki Amari; Adriano Piattelli; Karol Alí Apaza Alccayhuaman; Natalia Fortich Mesa; Mauro Ferri; Giovanna Iezzi; Daniele Botticelli
Journal:  Int J Implant Dent       Date:  2019-12-05
  1 in total