Literature DB >> 25662328

Current role of computed tomography-guided transthoracic needle biopsy of metastatic lung lesions.

Anna Galluzzo1, Claudio Genova, Salvatore Dioguardi, Massimo Midiri, Massimo Cajozzo.   

Abstract

AIM: As part of the Catania symposium on lung metastasectomy we reviewed our practice of computed tomography (CT)-guided percutaneous transthoracic needle biopsy of pulmonary metastatic lesions with particular emphasis on diagnostic accuracy and nature of complications lesions. MATERIALS &
METHODS: 25 patients with metastatic lesions of the lung have been evaluated between May 2010 and February 2014. Inclusion criteria consisted of patients with histologically confirmed, metastatic disease of the lung, those receiving a CT-guided needle biopsy, were at least 18 years of age; and with adequate hepatic, renal and hematological function. We recorded also the size of the sampled lesions, their distance from the pleura, the complications encountered (pneumothorax and thoracostomy tube placement), the cytological diagnosis and the outcome in all the cases.
RESULTS: CT-guided percutaneous transthoracic needle biopsy were performed on 23 of 25 patients with suspected lung metastases. 17 males and six females with a mean age of 71.4 years. The mean size of lesions was 4.2 cm (range: 1 to 17 cm). For CT-guided needle biopsy, an 18 gauge semi-automatic needle biopsy device was used. Of 23 biopsies, 20 (87%) yielded a correct diagnosis with specific histological typing for metastasis. Pneumothorax was the most common complication occurring in four cases (5.7%).
CONCLUSION: CT-guided percutaneous transthoracic needle biopsy is a firm, useful and safe technique for the diagnosis of suspected pulmonary metastases as it avoids open biopsy in most cases.

Entities:  

Keywords:  CT-guided biopsy; lung metastasis; transthoracic needle biopsy

Mesh:

Year:  2015        PMID: 25662328     DOI: 10.2217/fon.14.258

Source DB:  PubMed          Journal:  Future Oncol        ISSN: 1479-6694            Impact factor:   3.404


  3 in total

1.  CT-guided core needle biopsy of the lung in patients with primary malignancy suspected of lung metastasis: 5-year experience from a single institution.

Authors:  Jianbin Zhu; Xianlong Wang; Yaoming Qu; Zhibo Wen
Journal:  Diagn Interv Radiol       Date:  2021-07       Impact factor: 2.630

Review 2.  Medical imaging and nuclear medicine: a Lancet Oncology Commission.

Authors:  Hedvig Hricak; May Abdel-Wahab; Rifat Atun; Miriam Mikhail Lette; Diana Paez; James A Brink; Lluís Donoso-Bach; Guy Frija; Monika Hierath; Ola Holmberg; Pek-Lan Khong; Jason S Lewis; Geraldine McGinty; Wim J G Oyen; Lawrence N Shulman; Zachary J Ward; Andrew M Scott
Journal:  Lancet Oncol       Date:  2021-03-04       Impact factor: 41.316

3.  Risk factors associated with pulmonary hemorrhage and hemoptysis following percutaneous CT-guided transthoracic lung core needle biopsy: a retrospective study of 1,090 cases.

Authors:  Jianbin Zhu; Yaoming Qu; Xianlong Wang; Chunxiu Jiang; Jianhua Mo; Jiandong Xi; Zhibo Wen
Journal:  Quant Imaging Med Surg       Date:  2020-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.