Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: a feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm.

Yufei Wang1, David Joannic2, Patrick Delassus3, Alain Lalande4, Patrick Juillion1, Jean-François Fontaine5.   

Abstract

The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Abdominal aorta aneurysm; Aorta phantom; MRI; Measurement of strain fields; Metrology in medical imaging; Stereovision

Mesh:

Year:  2015        PMID: 25661521     DOI: 10.1016/j.jbiomech.2015.01.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Limb graft occlusion following endovascular aortic repair: Incidence, causes, treatment and prevention in a study cohort.

Authors:  Guoquan Wang; Shuiting Zhai; Tianxiao Li; Xuan Li; Danghui Lu; Bo Wang; Dongbin Zhang; Shuaitao Shi; Zhidong Zhang; Kai Liang; Kewei Zhang; Xiaoyang Fu; Kun Li; Weixiao Li
Journal:  Exp Ther Med       Date:  2017-06-23       Impact factor: 2.447

2.  Distensibility of Deformable Aortic Replicas Assessed by an Integrated In-Vitro and In-Silico Approach.

Authors:  Luigi Di Micco; Giulia Comunale; Stefano Bonvini; Paolo Peruzzo; Francesca Maria Susin
Journal:  Bioengineering (Basel)       Date:  2022-02-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.