Cheng-Chia Lee1,2,3, Ching-Jen Chen1, Benjamin Ball1, David Schlesinger1,4, Zhiyuan Xu1, Chun-Po Yen1, Jason Sheehan1,4. 1. Departments of 1 Neurological Surgery, and. 2. Department of Neurosurgery, Neurological Institute, Taipei Veterans General Hospital; and. 3. School of Medicine, National Yang-Ming University, Taipei, Taiwan, ROC. 4. Radiation Oncology, University of Virginia, Charlottesville, Virginia;
Abstract
OBJECT: Onyx, an ethylene-vinyl alcohol copolymer mixed in a dimethyl sulfoxide solvent, is currently one of the most widely used liquid materials for embolization of intracranial arteriovenous malformations (AVMs). The goal of this study was to define the risks and benefits of stereotactic radiosurgery (SRS) for patients who have previously undergone partial AVM embolization with Onyx. METHODS: Among a consecutive series of 199 patients who underwent SRS between January 2007 and December 2012 at the University of Virginia, 25 patients had Onyx embolization prior to SRS (the embolization group). To analyze the obliteration rates and complications, 50 patients who underwent SRS without prior embolization (the no-embolization group) were matched by propensity score method. The matched variables included age, sex, nidus volume before SRS, margin dose, Spetzler-Martin grade, Virginia Radiosurgery AVM Scale score, and median imaging follow-up period. RESULTS: After Onyx embolization, 18 AVMs were reduced in size. Total obliteration was achieved in 6 cases (24%) at a median of 27.5 months after SRS. In the no-embolization group, total obliteration was achieved in 20 patients (40%) at a median of 22.4 months after SRS. Kaplan-Meier analysis demonstrated obliteration rates of 17.7% and 34.1% in the embolization group at 2 and 4 years, respectively. In the no-embolization group, the corresponding obliteration rates were 27.0% and 55.9%. The between-groups difference in obliteration rates after SRS did not achieve statistical significance. The difference in complications, including adverse radiation effects, hemorrhage episodes, seizure control, and patient mortality also did not reach statistical significance. CONCLUSIONS: Onyx embolization can effectively reduce the size of many AVMs. This case-control study did not show any statistically significant difference in the rates of embolization or complications after SRS in patients who had previously undergone Onyx embolization and those who had not.
OBJECT: Onyx, an ethylene-vinyl alcohol copolymer mixed in a dimethyl sulfoxide solvent, is currently one of the most widely used liquid materials for embolization of intracranial arteriovenous malformations (AVMs). The goal of this study was to define the risks and benefits of stereotactic radiosurgery (SRS) for patients who have previously undergone partial AVM embolization with Onyx. METHODS: Among a consecutive series of 199 patients who underwent SRS between January 2007 and December 2012 at the University of Virginia, 25 patients had Onyx embolization prior to SRS (the embolization group). To analyze the obliteration rates and complications, 50 patients who underwent SRS without prior embolization (the no-embolization group) were matched by propensity score method. The matched variables included age, sex, nidus volume before SRS, margin dose, Spetzler-Martin grade, Virginia Radiosurgery AVM Scale score, and median imaging follow-up period. RESULTS: After Onyx embolization, 18 AVMs were reduced in size. Total obliteration was achieved in 6 cases (24%) at a median of 27.5 months after SRS. In the no-embolization group, total obliteration was achieved in 20 patients (40%) at a median of 22.4 months after SRS. Kaplan-Meier analysis demonstrated obliteration rates of 17.7% and 34.1% in the embolization group at 2 and 4 years, respectively. In the no-embolization group, the corresponding obliteration rates were 27.0% and 55.9%. The between-groups difference in obliteration rates after SRS did not achieve statistical significance. The difference in complications, including adverse radiation effects, hemorrhage episodes, seizure control, and patient mortality also did not reach statistical significance. CONCLUSIONS: Onyx embolization can effectively reduce the size of many AVMs. This case-control study did not show any statistically significant difference in the rates of embolization or complications after SRS in patients who had previously undergone Onyx embolization and those who had not.
Authors: Daniel Umansky; Benjamin W Corn; Ido Strauss; Natan Shtraus; Shlomi Constantini; Vladimir Frolov; Shimon Maimon; Andrew A Kanner Journal: Childs Nerv Syst Date: 2018-06-07 Impact factor: 1.475
Authors: Ching-Jen Chen; Dale Ding; Cheng-Chia Lee; Kathryn N Kearns; I Jonathan Pomeraniec; Christopher P Cifarelli; David E Arsanious; Roman Liscak; Jaromir Hanuska; Brian J Williams; Mehran B Yusuf; Shiao Y Woo; Natasha Ironside; Rebecca M Burke; Ronald E Warnick; Daniel M Trifiletti; David Mathieu; Monica Mureb; Carolina Benjamin; Douglas Kondziolka; Caleb E Feliciano; Rafael Rodriguez-Mercado; Kevin M Cockroft; Scott Simon; Heath B Mackley; Samer G Zammar; Neel T Patel; Varun Padmanaban; Nathan Beatson; Anissa Saylany; John Y K Lee; Jason P Sheehan Journal: J Neurosurg Date: 2020-12-11 Impact factor: 5.408
Authors: Myung Ji Kim; Kyung Won Chang; So Hee Park; Won Seok Chang; Jong Hee Chang; Jin Woo Chang; Hyun Ho Jung Journal: J Clin Med Date: 2021-05-19 Impact factor: 4.241