Literature DB >> 25655464

Asymmetric hip kinematics during gait in patients with unilateral total hip arthroplasty: in vivo 3-dimensional motion analysis.

Tsung-Yuan Tsai1, Dimitris Dimitriou1, Jing-Sheng Li1, Kwang Woo Nam1, Guoan Li2, Young-Min Kwon1.   

Abstract

Asymmetric limb loading has been reported in unilateral total hip arthroplasty (THA) patients during gait. However, restoration of 3D motion symmetry of the hip following unilateral THA remains unclear. The purpose of this study was to investigate the in vivo 3D kinematics of the hip in unilateral THA patients during gait. Eight unilateral THA patients were evaluated for both hips during treadmill gait using a dual fluoroscopic imaging system. Reduced hip range of motion in sagittal plane, decreased peak hip extension and asymmetric pelvic rotation of the THA were observed. Furthermore, significant pelvic anterior/posterior tilt asymmetry, higher internal rotation (increased by 8.6°±4.6°) during stance phase and higher adduction (increased by 4.5°±3.2°) during swing phase of the THA were found in this cohort of patients. The results demonstrated that there was 3D motion asymmetry of the hip and pelvis in unilateral THA patients during gait. The data could provide insights into optimizing kinematics and to restoring normal hip function after THA.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Fluoroscope; Gait; Hip; Kinematics; Total hip arthroplasty

Mesh:

Year:  2015        PMID: 25655464     DOI: 10.1016/j.jbiomech.2015.01.021

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  Step Length Asymmetry and Its Associations With Mechanical Energy Exchange, Function, and Fatigue After Total Hip Replacement.

Authors:  Chun-Hao Huang; Kharma C Foucher
Journal:  J Orthop Res       Date:  2019-04-26       Impact factor: 3.494

2.  Spine and lower body symmetry during treadmill walking in healthy individuals-In-vivo 3-dimensional kinematic analysis.

Authors:  Paul Gonzalo Arauz; Maria-Gabriela Garcia; Patricio Chiriboga; Sebastian Taco-Vasquez; Diego Klaic; Emilia Verdesoto; Bernard Martin
Journal:  PLoS One       Date:  2022-10-06       Impact factor: 3.752

3.  Spatio-temporal gait parameters obtained from foot-worn inertial sensors are reliable in healthy adults in single- and dual-task conditions.

Authors:  J Soulard; J Vaillant; R Balaguier; N Vuillerme
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

4.  Muscular strength after total hip arthroplasty. A prospective comparison of 3 surgical approaches.

Authors:  Siri B Winther; Vigdis S Husby; Olav A Foss; Tina S Wik; Svein Svenningsen; Monika Engdal; Kristin Haugan; Otto S Husby
Journal:  Acta Orthop       Date:  2015-08-27       Impact factor: 3.717

5.  Validation of inertial measurement units with optical tracking system in patients operated with Total hip arthroplasty.

Authors:  Roland Zügner; Roy Tranberg; John Timperley; Diana Hodgins; Maziar Mohaddes; Johan Kärrholm
Journal:  BMC Musculoskelet Disord       Date:  2019-02-06       Impact factor: 2.362

6.  Towards an Inertial Sensor-Based Wearable Feedback System for Patients after Total Hip Arthroplasty: Validity and Applicability for Gait Classification with Gait Kinematics-Based Features.

Authors:  Wolfgang Teufl; Bertram Taetz; Markus Miezal; Michael Lorenz; Juliane Pietschmann; Thomas Jöllenbeck; Michael Fröhlich; Gabriele Bleser
Journal:  Sensors (Basel)       Date:  2019-11-16       Impact factor: 3.576

7.  Optimizing the Femoral Offset for Restoring Physiological Hip Muscle Function in Patients With Total Hip Arthroplasty.

Authors:  Xiangjun Hu; Nan Zheng; Yunsu Chen; Kerong Dai; Dimitris Dimitriou; Huiwu Li; Tsung-Yuan Tsai
Journal:  Front Bioeng Biotechnol       Date:  2021-03-30

8.  Does treadmill workstation use affect user's kinematic gait symmetry?

Authors:  Paul Gonzalo Arauz; María-Gabriela García; Mauricio Velez; Cesar León; Francisco Velez; Bernard Martin
Journal:  PLoS One       Date:  2021-12-14       Impact factor: 3.240

9.  Adverse effects of total hip arthroplasty on the hip abductor and adductor muscle lengths and moment arms during gait.

Authors:  Xiangjun Hu; Nan Zheng; Wei-Chun Hsu; Jingwei Zhang; Huiwu Li; Yunsu Chen; Kerong Dai; Tsung-Yuan Tsai
Journal:  J Orthop Surg Res       Date:  2020-08-12       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.