Literature DB >> 25652518

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images.

Edwin C I Ao1, Nien-Yun Wu2, Shyh-Jen Wang3, Na Song4, Greta S P Mok1.   

Abstract

PURPOSE: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry.
METHODS: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5°/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed.
RESULTS: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (-15.50 ± 5.59)% to (-2.12 ± 1.05)% and (-7.28 ± 2.30)% to (-0.23 ± 0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods.
CONCLUSIONS: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

Entities:  

Mesh:

Year:  2015        PMID: 25652518     DOI: 10.1118/1.4906242

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Technical note: A wearable radiation measurement system for collection of patient-specific time-activity data in radiopharmaceutical therapy: system design and Monte Carlo simulation results.

Authors:  Silvio Morganti; Francesco Collamati; Riccardo Faccini; Giuseppe Iaccarino; Carlo Mancini-Terracciano; Riccardo Mirabelli; Francesca Nicolanti; Massimiliano Pacilio; Antonella Soriani; Elena Solfaroli-Camillocci
Journal:  Med Phys       Date:  2021-11-23       Impact factor: 4.506

Review 2.  Implications of physics, chemistry and biology for dosimetry calculations using theranostic pairs.

Authors:  Cassandra Miller; Julie Rousseau; Caterina F Ramogida; Anna Celler; Arman Rahmim; Carlos F Uribe
Journal:  Theranostics       Date:  2022-01-01       Impact factor: 11.600

3.  BIGDOSE: software for 3D personalized targeted radionuclide therapy dosimetry.

Authors:  Tiantian Li; Licheng Zhu; Zhonglin Lu; Na Song; Ko-Han Lin; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2020-01

Review 4.  Quantitative Imaging for Targeted Radionuclide Therapy Dosimetry - Technical Review.

Authors:  Tiantian Li; Edwin C I Ao; Bieke Lambert; Boudewijn Brans; Stefaan Vandenberghe; Greta S P Mok
Journal:  Theranostics       Date:  2017-10-13       Impact factor: 11.556

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.