Literature DB >> 25651914

Actigraphy combined with EEG compared to polysomnography in sleep apnea patients.

Ingo Fietze1, Thomas Penzel, Markku Partinen, Jochen Sauter, Gert Küchler, Alexander Suvoro, Holger Hein.   

Abstract

An actigraph extended with electroencephalography (EEG), electroocculography (EOG) and electromyography (EMG) was compared to polysomnography in two studies on patients suffering from sleep disordered breathing. Study A with 30 subjects used a single lead EEG, and study B with 20 subjects used EOG and EMG in addition. Sleep was scored according to Rechtschaffen and Kales rules. Total sleep time (TST), sleep period time (SPT), sleep efficiency (SE), sustained sleep efficiency (SSE), sleep-onset latency (SL), and sleep stages were compared. For study A an epoch-by-epoch comparison of sleep stages revealed an overall agreement of 74.2%. Correlations were high for SE (0.98, p < 0.001), SSE (0.98, p < 0.001), TST (0.99, p < 0.001), SPT (0.99, p < 0.001), and SL (0.98, p < 0.001). Regarding the sleep stages, correlations were high for rapid eye movement (REM) (0.83, p < 0.001), light-sleep (0.78, p < 0.001), and deep sleep (0.73, p < 0.001). For study B, results of an epoch-by-epoch comparison of sleep stages showed an overall agreement of 75.5%. Correlations were high for SE (0.98, p < 0.001), SSE (0.98, p < 0.001), TST (0.87, p < 0.001), SL (0.98, p < 0.001), SPT (0.94, p < 0.001), and for rapid eye movement (REM) (0.91, p < 0.001), light-sleep (0.74, p < 0.001), and deep sleep (0.89, p < 0.001). In summary the study revealed high agreement between polysomnography and single lead EEG in sleep apnea patients. Deviations for REM were slightly higher for the single lead EEG compared to single lead EEG plus EOG/EMG. Both simplified systems proved to be reliable for comfortable out-patient sleep recording.

Entities:  

Mesh:

Year:  2015        PMID: 25651914     DOI: 10.1088/0967-3334/36/3/385

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Performance of a New Portable Wireless Sleep Monitor.

Authors:  Magdy Younes; Marc Soiferman; Wayne Thompson; Eleni Giannouli
Journal:  J Clin Sleep Med       Date:  2017-02-15       Impact factor: 4.062

2.  Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography.

Authors:  Janna Mantua; Nickolas Gravel; Rebecca M C Spencer
Journal:  Sensors (Basel)       Date:  2016-05-05       Impact factor: 3.576

3.  The acute effects of aerobic exercise on sleep in patients with depression: study protocol for a randomized controlled trial.

Authors:  Gavin Brupbacher; Doris Straus; Hildburg Porschke; Thea Zander-Schellenberg; Markus Gerber; Roland von Känel; Arno Schmidt-Trucksäss
Journal:  Trials       Date:  2019-06-13       Impact factor: 2.279

4.  Dexmedetomidine Improves Non-rapid Eye Movement Stage 2 Sleep in Children in the Intensive Care Unit on the First Night After Laparoscopic Surgery.

Authors:  Xian Zhang; Li Chang; Shou-Dong Pan; Fu-Xia Yan
Journal:  Front Pediatr       Date:  2022-04-27       Impact factor: 3.418

5.  Poor Sleep in Multiple Sclerosis Correlates with Beck Depression Inventory Values, but Not with Polysomnographic Data.

Authors:  Christian Veauthier; Gunnar Gaede; Helena Radbruch; Klaus-Dieter Wernecke; Friedemann Paul
Journal:  Sleep Disord       Date:  2016-01-18

6.  The acute effects of aerobic exercise on sleep in patients with unipolar depression: a randomized controlled trial.

Authors:  Gavin Brupbacher; Thea Zander-Schellenberg; Doris Straus; Hildburg Porschke; Denis Infanger; Markus Gerber; Roland von Känel; Arno Schmidt-Trucksäss
Journal:  Sleep       Date:  2021-11-12       Impact factor: 5.849

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.