Literature DB >> 25648781

Dynamic in vivo evaluation of radiocarpal contact after a 4-corner arthrodesis.

Mahyar Foumani1, Simon D Strackee2, Carlijn M Stekelenburg2, Leendert Blankevoort2, Geert J Streekstra2.   

Abstract

PURPOSE: To understand the mechanisms that preserve joint integrity after 4-corner arthrodesis (FCA).
METHODS: We investigated the long-term changes of the radiolunate articulation after an FCA for different motions of the wrist in a cross-sectional study that included wrists of 10 healthy participants and both operated and nonoperated wrists of 8 individuals who had undergone FCA on 1 side. The average postoperative follow-up period of the FCA group was 5.7 years. The radiolunate articulation was assessed from dynamic 3-dimensional distance maps during wrist motion. Contact surface area, centroid position of the articular area, and distance between radiolunate articular surfaces were measured and compared between healthy subjects and operated and nonoperated wrists of FCA patients.
RESULTS: The total radiolunate articulation area was larger in patients with FCA. The average radiolunate joint space thickness was preserved in the operated FCA wrists. The centroid of the articulation area was shifted radially and dorsally in FCA wrists.
CONCLUSIONS: Changes of the motion pattern of the lunate during radioulnar deviation and flexion-extension of the wrist after FCA can explain the shift of the centroid radially and dorsally. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic IV.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Four-corner arthrodesis; biomechanics of the wrist joint; dynamic imaging of the wrist; quantification of osteoarthritis

Mesh:

Year:  2015        PMID: 25648781     DOI: 10.1016/j.jhsa.2014.11.028

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  3 in total

1.  Scapholunate instability: improved detection with semi-automated kinematic CT analysis during stress maneuvers.

Authors:  Waled Abou Arab; Aymeric Rauch; Mohammad B Chawki; Francois Dap; Gilles Dautel; Alain Blum; Pedro Augusto Gondim Teixeira
Journal:  Eur Radiol       Date:  2018-04-30       Impact factor: 5.315

2.  Four-dimensional rotational radiographic scanning of the wrist in patients after proximal row carpectomy.

Authors:  A Peymani; M Foumani; J G G Dobbe; S D Strackee; G J Streekstra
Journal:  J Hand Surg Eur Vol       Date:  2017-07-06

3.  Accuracy of manual and automatic placement of an anatomical coordinate system for the full or partial radius in 3D space.

Authors:  Marieke G A de Roo; Johannes G G Dobbe; Abbas Peymani; Anne D van der Made; Simon D Strackee; Geert J Streekstra
Journal:  Sci Rep       Date:  2020-05-15       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.