Literature DB >> 25648195

A cell-based sensor of fluid shear stress for microfluidics.

Sarvesh Varma1, Joel Voldman.   

Abstract

Microsystems designed for cell-based studies or applications inherently require fluid handling. Flows within such systems inevitably generate fluid shear stress (FSS) that may adversely affect cell health. Simple assays of cell viability, morphology or growth are typically reported to indicate any gross disturbances to cell physiology. However, no straightforward metric exists to specifically evaluate physiological implications of FSS within microfluidic devices, or among competing microfluidic technologies. This paper presents the first genetically encoded cell sensors that fluoresce in a quantitative fashion upon FSS pathway activation. We picked a widely used cell line (NIH3T3s) and created a transcriptional cell-sensor where fluorescence turns on when transcription of a relevant FSS-induced protein is initiated. Specifically, we chose Early Growth Factor-1 (a mechanosensitive protein) upregulation as the node for FSS detection. We verified our sensor pathway specificity and functionality by noting induced fluorescence in response to chemical induction of the FSS pathway, seen both through microscopy and flow cytometry. Importantly, we found our cell sensors to be inducible by a range of FSS intensities and durations, with a limit of detection of 2 dynes cm(-2) when applied for 30 minutes. Additionally, our cell-sensors proved their versatility by showing induction sensitivity when made to flow through an inertial microfluidic device environment with typical flow conditions. We anticipate these cell sensors to have wide application in the microsystems community, allowing the device designer to engineer systems with acceptable FSS, and enabling the end-user to evaluate the impact of FSS upon their assay of interest.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25648195      PMCID: PMC4443851          DOI: 10.1039/c4lc01369g

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  54 in total

Review 1.  Molecular basis of the effects of shear stress on vascular endothelial cells.

Authors:  Yi-Shuan J Li; Jason H Haga; Shu Chien
Journal:  J Biomech       Date:  2005-10       Impact factor: 2.712

2.  Equilibrium separation and filtration of particles using differential inertial focusing.

Authors:  Dino Di Carlo; Jon F Edd; Daniel Irimia; Ronald G Tompkins; Mehmet Toner
Journal:  Anal Chem       Date:  2008-02-15       Impact factor: 6.986

3.  Bright far-red fluorescent protein for whole-body imaging.

Authors:  Dmitry Shcherbo; Ekaterina M Merzlyak; Tatiana V Chepurnykh; Arkady F Fradkov; Galina V Ermakova; Elena A Solovieva; Konstantin A Lukyanov; Ekaterina A Bogdanova; Andrey G Zaraisky; Sergey Lukyanov; Dmitriy M Chudakov
Journal:  Nat Methods       Date:  2007-08-26       Impact factor: 28.547

4.  Attenuation of extrinsic signaling reveals the importance of matrix remodeling on maintenance of embryonic stem cell self-renewal.

Authors:  Laralynne M Przybyla; Joel Voldman
Journal:  Proc Natl Acad Sci U S A       Date:  2012-01-03       Impact factor: 11.205

Review 5.  Flow-mediated endothelial mechanotransduction.

Authors:  P F Davies
Journal:  Physiol Rev       Date:  1995-07       Impact factor: 37.312

6.  Nitric oxide regulates shear stress-induced early growth response-1. Expression via the extracellular signal-regulated kinase pathway in endothelial cells.

Authors:  J J Chiu; B S Wung; H J Hsieh; L W Lo; D L Wang
Journal:  Circ Res       Date:  1999-08-06       Impact factor: 17.367

7.  Microfluidic devices for studies of shear-dependent platelet adhesion.

Authors:  Edgar Gutierrez; Brian G Petrich; Sanford J Shattil; Mark H Ginsberg; Alex Groisman; Ana Kasirer-Friede
Journal:  Lab Chip       Date:  2008-07-23       Impact factor: 6.799

Review 8.  Shear stress, reactive oxygen species, and arterial structure and function.

Authors:  Hanke L Matlung; Erik N T P Bakker; Ed VanBavel
Journal:  Antioxid Redox Signal       Date:  2009-07       Impact factor: 8.401

9.  Flow activation of AMP-activated protein kinase in vascular endothelium leads to Krüppel-like factor 2 expression.

Authors:  Angela Young; Wei Wu; Wei Sun; H Benjamin Larman; Harry B Larman; Nanping Wang; Yi-Shuan Li; John Y Shyy; Shu Chien; Guillermo García-Cardeña
Journal:  Arterioscler Thromb Vasc Biol       Date:  2009-08-20       Impact factor: 8.311

10.  Spatially resolved shear distribution in microfluidic chip for studying force transduction mechanisms in cells.

Authors:  Jianbin Wang; Jinseok Heo; Susan Z Hua
Journal:  Lab Chip       Date:  2009-11-17       Impact factor: 6.799

View more
  11 in total

1.  Cassie-Baxter Surfaces for Reversible, Barrier-Free Integration of Microfluidics and 3D Cell Culture.

Authors:  Soroosh Torabi; Linzhang Li; Jonathan Grabau; Madison Sands; Brad J Berron; Ren Xu; Christine A Trinkle
Journal:  Langmuir       Date:  2019-07-23       Impact factor: 3.882

2.  Microscale impeller pump for recirculating flow in organs-on-chip and microreactors.

Authors:  Sophie R Cook; Hannah B Musgrove; Amy L Throckmorton; Rebecca R Pompano
Journal:  Lab Chip       Date:  2022-02-01       Impact factor: 6.799

Review 3.  Tissutal and Fluidic Aspects in Osteopathic Manual Therapy: A Narrative Review.

Authors:  Marco Verzella; Erika Affede; Luca Di Pietrantonio; Vincenzo Cozzolino; Luca Cicchitti
Journal:  Healthcare (Basel)       Date:  2022-05-31

Review 4.  In Vitro Flow Chamber Design for the Study of Endothelial Cell (Patho)Physiology.

Authors:  Meghan E Fallon; Rick Mathews; Monica T Hinds
Journal:  J Biomech Eng       Date:  2022-02-01       Impact factor: 2.097

5.  Laser-fabricated cell patterning stencil for single cell analysis.

Authors:  Jacob J Messner; Honor L Glenn; Deirdre R Meldrum
Journal:  BMC Biotechnol       Date:  2017-12-19       Impact factor: 2.563

Review 6.  Caring for cells in microsystems: principles and practices of cell-safe device design and operation.

Authors:  Sarvesh Varma; Joel Voldman
Journal:  Lab Chip       Date:  2018-11-06       Impact factor: 6.799

7.  The Viability of Single Cancer Cells after Exposure to Hydrodynamic Shear Stresses in a Spiral Microchannel: A Canine Cutaneous Mast Cell Tumor Model.

Authors:  Dettachai Ketpun; Achariya Sailasuta; Thammawit Suwannaphan; Sudchaya Bhanpattanakul; Alongkorn Pimpin; Werayut Srituravanich; Witsaroot Sripumkhai; Wutthinan Jeamsaksiri; Prapruddee Piyaviriyakul
Journal:  Micromachines (Basel)       Date:  2017-12-28       Impact factor: 2.891

8.  Microfluidic Device for On-Chip Immunophenotyping and Cytogenetic Analysis of Rare Biological Cells.

Authors:  Kumuditha M Weerakoon-Ratnayake; Swarnagowri Vaidyanathan; Nicholas Larky; Kavya Dathathreya; Mengjia Hu; Jilsha Jose; Shalee Mog; Keith August; Andrew K Godwin; Mateusz L Hupert; Malgorzata A Witek; Steven A Soper
Journal:  Cells       Date:  2020-02-24       Impact factor: 6.600

9.  Biomechanical Regulation of Hematopoietic Stem Cells in the Developing Embryo.

Authors:  Paulina D Horton; Sandeep P Dumbali; Krithikaa Rajkumar Bhanu; Miguel F Diaz; Pamela L Wenzel
Journal:  Curr Tissue Microenviron Rep       Date:  2021-01-26

10.  A microfluidics-based wound-healing assay for studying the effects of shear stresses, wound widths, and chemicals on the wound-healing process.

Authors:  Jin-Young Lin; Kai-Yin Lo; Yung-Shin Sun
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.