Literature DB >> 25643671

Influence of various fluoride agents on working properties and surface characteristics of uncoated, rhodium coated and nitrified nickel-titanium orthodontic wires.

Višnja Katić1, Vilko Mandić, Damir Ježek, Gorana Baršić, Stjepan Špalj.   

Abstract

OBJECTIVE: To analyze the effect of various fluoride formulations in commercially available agents on working properties of various nickel-titanium orthodontic wires.
MATERIALS AND METHODS: Uncoated (NiTi), rhodium coated (RhNiTi) and nitrified (NNiTi) wires were immersed to dH2O, MiPaste, Elmex and Mirafluor for 1 h. Unloading slope characteristics (average force, bending action of the force and average plateau length) and the percentage of useable constant force during unloading were observed. Surface roughness (Ra) was measured. SEM and EDS were used for observation of the surface.
RESULTS: NiTi had decreased loading and unloading elastic modulus (E) and yield strength (YS) after immersion to MIPaste and Mirafluor. The unloading YS decreased in the RhNiTi by the MIPaste. The loading and unloading YS of the NNiTi increased in Elmex and increased average plateau force. RhNiTi showed higher average plateau length and the percentage of useful constant force during unloading in Mirafluor and the average plateau force lowered after immersion to MIPaste. The unloading slope characteristics for NiTi were affected by all three prophylactic agents, mostly by Mirafluor, and produced significantly lower forces during both loading and unloading, similarly to the NNiTi wires. The RhNiTi had the lowest forces during both loading and unloading in MIPaste. All results were at significance; p<0.05. Difference in Ra was observed for RhNiTi after immersion to the MI Paste (p<0.001; η2=0.761).
CONCLUSION: The NiTi and NNiTi wires lose less working force when combined with Elmex. The RhNiTi improve their working properties with Mirafluor and deteriorate when combined with MiPaste.

Entities:  

Keywords:  chemically induced; corrosion; mechanical; orthodontic appliance; roughness; stress

Mesh:

Substances:

Year:  2015        PMID: 25643671     DOI: 10.3109/00016357.2014.980847

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  2 in total

1.  Effect of 0.05% Sodium Fluoride Mouthwash on Surface Roughness and Friction between Ceramic Brackets and Rhodium-Coated and Uncoated Stainless Steel Wires.

Authors:  Tahereh Hosseinzadeh Nik; Hannaneh Ghadirian; Tabassom Hooshmand; Mohammad Javad Kharazifard; Maryam Nasiri; Maryam Javaheri Mahd
Journal:  Front Dent       Date:  2019-04-30

2.  Assessment of Nickel and Chromium Level in Gingival Crevicular Fluid in Patients Undergoing Orthodontic Treatment with or without Fluoridated Tooth Paste.

Authors:  Amrita Pritam; Arya Priyadarshini; Kashif Hussain; Abhijit Kumar; Nikhil Kumar; Aniruddha Malakar
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.