Literature DB >> 25640582

Electrochemical hematocrit determination in a direct current microfluidic device.

Hwi Yong Lee1, Cedrick Barber, Jessika A Rogers, Adrienne R Minerick.   

Abstract

Hematocrit (HCT) tests are widely performed to screen blood donors and to diagnose medical conditions. Current HCT test methods include conventional microhematocrit, Coulter counter, CuSO4 specific gravity, and conductivity-based point-of-care (POC) HCT devices, which can be either expensive, environmentally inadvisable, or complicated. In the present work, we introduce a new and simple microfluidic system for a POC HCT determination. HCT was determined by measuring current responses of blood under 100 V DC for 1 min in a microfluidic device containing a single microchannel with dimensions of 180 μm by 70 μm and 10 mm long. Current responses of red blood cell (RBC) suspensions in PBS or separately plasma at HCT concentrations of 10, 20, 25, 30, 35, 40, 45, 50, 55, 60, and 70 vol% were measured to show feasibility of the microfluidic system for HCT determination. Key parameters affecting current responses included electrolysis bubbles and irreversible RBC adsorption; parameters were optimized via addition of nonionic surfactant Triton X-100 into sample solution and carbonizing electrode surfaces. The linear trend line of current responses over a range of RBC concentrations were obtained in both PBS and plasma. This work suggested that a simple microfluidic device could be a promising platform for a new POC HCT device.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Hematocrit; Medical diagnostics; Microdevice; Platinum electrodes; Red blood cell

Mesh:

Substances:

Year:  2015        PMID: 25640582     DOI: 10.1002/elps.201400466

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  Periodic and simultaneous quantification of blood viscosity and red blood cell aggregation using a microfluidic platform under in-vitro closed-loop circulation.

Authors:  Yang Jun Kang
Journal:  Biomicrofluidics       Date:  2018-04-09       Impact factor: 2.800

2.  Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations.

Authors:  Yang Jun Kang
Journal:  Sensors (Basel)       Date:  2017-09-06       Impact factor: 3.576

3.  A Disposable Blood-on-a-Chip for Simultaneous Measurement of Multiple Biophysical Properties.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2018-09-20       Impact factor: 2.891

4.  Quantitative Measurement and Evaluation of Red Blood Cell Aggregation in Normal Blood Based on a Modified Hanai Equation.

Authors:  Jianming Wen; Nen Wan; Huilu Bao; Jianping Li
Journal:  Sensors (Basel)       Date:  2019-03-04       Impact factor: 3.576

5.  Experimental Investigation of Air Compliance Effect on Measurement of Mechanical Properties of Blood Sample Flowing in Microfluidic Channels.

Authors:  Yang Jun Kang
Journal:  Micromachines (Basel)       Date:  2020-04-28       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.