Measurement of quantitative viscoelasticity of bovine corneas based on lamb wave dispersion properties.

Xinyu Zhang1, Yin Yin1, Yanrong Guo1, Ning Fan2, Haoming Lin1, Fulong Liu1, Xianfen Diao1, Changfeng Dong3, Xin Chen4, Tianfu Wang1, Siping Chen1.   

Abstract

The viscoelastic properties of the human cornea can provide valuable information for clinical applications such as the early detection of corneal diseases, better management of corneal surgery and treatment and more accurate measurement of intra-ocular pressure. However, few techniques are capable of quantitatively and non-destructively assessing corneal biomechanics in vivo. The cornea can be regarded as a thin plate in which the vibration induced by an external vibrator propagates as a Lamb wave, the properties of which depend on the thickness and biomechanics of the tissue. In this study, pulses of ultrasound radiation force with a repetition frequency of 100 or 200 Hz were applied to the apex of corneas, and the linear-array transducer of a SonixRP system was used to track the tissue motion in the radial direction. Shear elasticity and viscosity were estimated from the phase velocities of the A0 Lamb waves. To assess the effectiveness of the method, some of the corneas were subjected to collagen cross-linking treatment, and the changes in mechanical properties were validated with a tensile test. The results indicated that the shear modulus was 137 ± 37 kPa and the shear viscosity was 3.01 ± 2.45 mPa · s for the group of untreated corneas and 1145 ± 267 kPa and was 0.16 ± 0.11 mPa · s for the treated group, respectively, implying a significant increase in elasticity and a significant decrease in viscosity after collagen cross-linking treatment. This result is in agreement with the results of the mechanical tensile test and with reports in the literature. This initial investigation illustrated the ability of this ultrasound-based method, which uses the velocity dispersion of low-frequency A0 Lamb waves, to quantitatively assess both the elasticity and viscosity of corneas. Future studies could discover ways to optimize this system and to determine the feasibility of using this method in clinical situations.
Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Corneas; Cross-linking therapy; Elastography; Lamb waves; Radiation force; Ultrasound; Viscoelasticity

Mesh:

Year:  2015        PMID: 25638310     DOI: 10.1016/j.ultrasmedbio.2014.12.017

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography.

Authors:  Manmohan Singh; Jiasong Li; Zhaolong Han; Raksha Raghunathan; Achuth Nair; Chen Wu; Chih-Hao Liu; Salavat Aglyamov; Michael D Twa; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-12-19       Impact factor: 3.732

Review 2.  Application of Elastography for the Noninvasive Assessment of Biomechanics in Engineered Biomaterials and Tissues.

Authors:  Woong Kim; Virginia L Ferguson; Mark Borden; Corey P Neu
Journal:  Ann Biomed Eng       Date:  2016-01-20       Impact factor: 3.934

3.  Quantifying the effects of hydration on corneal stiffness with noncontact optical coherence elastography.

Authors:  Manmohan Singh; Zhaolong Han; Jiasong Li; Srilatha Vantipalli; Salavat R Aglyamov; Michael D Twa; Kirill V Larin
Journal:  J Cataract Refract Surg       Date:  2018-07-23       Impact factor: 3.351

4.  Ultrafast ultrasound imaging of surface acoustic waves induced by laser excitation compared with acoustic radiation force.

Authors:  Lingyi Zhao; Don Vanderlaan; Heechul Yoon; Jingfei Liu; Changhui Li; Stanislav Y Emelianov
Journal:  Opt Lett       Date:  2020-04-01       Impact factor: 3.776

5.  Estimation of the mechanical properties of the eye through the study of its vibrational modes.

Authors:  M Á Aloy; J E Adsuara; P Cerdá-Durán; M Obergaulinger; J J Esteve-Taboada; T Ferrer-Blasco; R Montés-Micó
Journal:  PLoS One       Date:  2017-09-18       Impact factor: 3.240

Review 6.  Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method.

Authors:  Robert Koprowski; Sławomir Wilczyński
Journal:  J Healthc Eng       Date:  2018-02-11       Impact factor: 2.682