A study of polymerization shrinkage kinetics using digital image correlation.

Andrew Lau1, Jianying Li1, Young Cheul Heo1, Alex Fok2.   

Abstract

OBJECTIVE: To investigate the polymerization shrinkage kinetics of dental resin composites by measuring in real time the full-field shrinkage strain using a novel technique based on digital image correlation (DIC).
METHODS: Polymerization shrinkage in resin composite specimens (Filtek LS and Z100) was measured as a function of time and position. The main experimental setup included a CCD camera and an external shutter inversely synchronized to that of the camera. The specimens (2 mm × 4 mm × 5 mm) were irradiated for 40s at 1200 mW/cm(2), while alternating image acquisition and obstruction of the curing light occurred at 15 fps. The acquired images were processed using proprietary software to obtain the full-field strain maps as a function of time.
RESULTS: Z100 showed a higher final shrinkage value and rate of development than LS. The final volumetric shrinkage for Z100 and LS were 1.99% and 1.19%, respectively. The shrinkage behavior followed an established shrinkage strain kinetics model. The corresponding characteristic time and reaction order exponent for LS and Z100 were calculated to be approximately 23s and 0.84, and 14s and 0.7, respectively, at a distance of 1.0mm from the irradiated surface, the position where maximum shrinkage strain occurred. Thermal expansion from the exothermic reaction could have affected the accuracy of these parameters. SIGNIFICANCE: The new DIC method using an inversely synchronized shutter provided realtime, full-field results that could aid in assessing the shrinkage strain kinetics of dental resin composites as a function of specimen depth. It could also help determine the optimal curing modes for dental resin composites.
Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Digital image correlation (DIC); Inversely synchronized shutter; Polymerization shrinkage kinetics; Real-time measurement; Resin composite

Mesh:

Substances:

Year:  2015        PMID: 25637317     DOI: 10.1016/j.dental.2015.01.001

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Application of polymeric porcelain color-masking cast posts in the aesthetic repair of anterior teeth: a case report.

Authors:  Yu-Xin Lou; Wei Ren; Bo Dong; Xing-Qiang Yang; Lei Zhao; Yu-Qing Lu; Xue-Qi Gan; Li Yue
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2021-02-01

2.  Remineralizing amorphous calcium phosphate based composite resins: the influence of inert fillers on monomer conversion, polymerization shrinkage, and microhardness.

Authors:  Danijela Marović; Kristina Šariri; Nazif Demoli; Mira Ristić; Karl-Anton Hiller; Drago Škrtić; Martin Rosentritt; Gottfried Schmalz; Zrinka Tarle
Journal:  Croat Med J       Date:  2016-10-31       Impact factor: 1.351

3.  Post-gel polymerisation shrinkage profiling of polymer biomaterials using a chirped fibre Bragg grating.

Authors:  Ginu Rajan; Alex Wong; Paul Farrar; Gangadhara B Prusty
Journal:  Sci Rep       Date:  2021-01-14       Impact factor: 4.379

4.  Shrinkage Stress and Temperature Variation in Resin Composites Cured via Different Photoactivation Methods: Insights for Standardisation of the Photopolymerisation.

Authors:  Guilherme Dos Santos Sousa; Gabriel Felipe Guimarães; Edilmar Marcelino; José Eduardo Petit Rodokas; Arilson José de Oliveira Júnior; Ivana Cesarino; Alcides Lopes Leão; Carla Dos Santos Riccardi; Mohammad Arjmand; Rafael Plana Simões
Journal:  Polymers (Basel)       Date:  2021-06-23       Impact factor: 4.329

5.  Longer-Term Postcure Measurement of Cuspal Deformation Induced by Dimensional Changes in Dental Materials.

Authors:  A Falsafi; J D Oxman; P-H Tse; T T Ton
Journal:  Int J Dent       Date:  2015-07-16

6.  3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements.

Authors:  Aleksandra Mitrović; Dušan Antonović; Ivan Tanasić; Nenad Mitrović; Gordana Bakić; Dejana Popović; Miloš Milošević
Journal:  Biomed Res Int       Date:  2019-11-17       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.