Literature DB >> 25636548

Appropriate use of ionizing radiation in orthodontic practice and research.

Ahmad A Abdelkarim1.   

Abstract

Ionizing radiation revolutionized medicine and dentistry in the past century. It has well-documented benefits in orthodontics, and these benefits outweigh the risks. Three-dimensional cone-beam computed tomography produces images that contain significantly more information than do traditional radiographs but generally exposes patients to more radiation. A group of pediatric radiologists initiated the Image Gently Campaign to raise awareness of the need to adjust the radiation dose when imaging children. The key principles of this campaign are justification, optimization, and dose limits. Orthodontists should adhere to the directive to keep radiation "as low as reasonably achievable." Prescribing radiographic imaging is specific to each orthodontic patient and requires judicious clinical judgment to maximize the benefits and minimize the harm.
Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25636548     DOI: 10.1016/j.ajodo.2014.11.010

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  5 in total

Review 1.  Cone-Beam Computed Tomography in Orthodontics.

Authors:  Ahmad Abdelkarim
Journal:  Dent J (Basel)       Date:  2019-09-02

2.  Accuracy of a Method to Monitor Root Position Using a 3D Digital Crown/Root Model during Orthodontic Treatments.

Authors:  Kaho Ogawa; Yoshiki Ishida; Yukinori Kuwajima; Cliff Lee; Jacob R Emge; Mitsuru Izumisawa; Kazuro Satoh; Shigemi Ishikawa-Nagai; John D Da Silva; Chia-Yu Chen
Journal:  Tomography       Date:  2022-02-23

3.  Maxillary second molar impaction in the adjacent ectopic third molar: Report of five rare cases.

Authors:  Bernardo Q Souki; Paula L Cheib; Gabriela M de Brito; Larissa S M C Pinto
Journal:  Contemp Clin Dent       Date:  2015 Jul-Sep

4.  Accuracy of three-dimensional cephalograms generated using a biplanar imaging system.

Authors:  Ha-Yeon Park; Jae-Seo Lee; Jin-Hyoung Cho; Hyeon-Shik Hwang; Kyung-Min Lee
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

5.  Morphometric Analysis of the Mandibular Canal, Anterior Loop, and Mental Foramen: A Cone-Beam Computed Tomography Evaluation.

Authors:  Altayeb Abdalla Ahmed; Rawia Mohamed Ahmed; Ahmed Jamleh; Gianrico Spagnuolo
Journal:  Int J Environ Res Public Health       Date:  2021-03-24       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.