Hemodynamic changes and retrograde flow in LVAD failure.

Guruprasad A Giridharan1, Steven C Koenig, Kevin G Soucy, Young Choi, Tohid Pirbodaghi, Carlo R Bartoli, Gretel Monreal, Michael A Sobieski, Erin Schumer, Allen Cheng, Mark S Slaughter.   

Abstract

In the event of left ventricular assist device (LVAD) failure, we hypothesized that rotary blood pumps will experience significant retrograde flow and induce adverse physiologic responses. Catastrophic LVAD failure was investigated in computer simulation with pulsatile, axial, and centrifugal LVAD, mock flow loop with pulsatile (PVAD) and centrifugal (ROTAFLOW), and healthy and chronic ischemic heart failure bovine models with pulsatile (PVAD), axial (HeartMate II), and centrifugal (HVAD) pumps. Simulated conditions were LVAD "off" with outflow graft clamped (baseline), LVAD "off" with outflow graft unclamped (LVAD failure), and LVAD "on" (5 L/min). Hemodynamics (aortic and ventricular blood pressures, LVAD flow, and left ventricular volume), echocardiography (cardiac volumes), and end-organ perfusion (regional blood flow microspheres) were measured and analyzed. Retrograde flow was observed with axial and centrifugal rotary pumps during LVAD failure in computer simulation (axial = -3.4 L/min, centrifugal = -2.8 L/min), mock circulation (pulsatile = -0.1 L/min, centrifugal = -2.7 L/min), healthy (pulsatile = -1.2 ± 0.3 L/min, axial = -2.2 ± 0.2 L/min, centrifugal = -1.9 ± 0.3 L/min), and ischemic heart failure (centrifugal = 2.2 ± 0.7 L/min) bovine models for all test conditions (p < 0.05). Differences between axial and centrifugal LVAD were statistically indiscernible. Retrograde flow increased ventricular end-systolic and end-diastolic volumes and workload, and decreased myocardial and end-organ perfusion during LVAD failure compared with baseline, LVAD support, and pulsatile LVAD failure.

Entities:  

Mesh:

Year:  2015        PMID: 25635935     DOI: 10.1097/MAT.0000000000000200

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

Review 1.  Percutaneous Transcatheter Therapies for the Management of Left Ventricular Assist Device Complications.

Authors:  Rohan J Kalathiya; Jonathan Grinstein; Nir Uriel; Atman P Shah
Journal:  J Invasive Cardiol       Date:  2017-02-15       Impact factor: 2.022

2.  Left Ventricular Assist Device Deactivation via Percutaneous Closure of the Outflow Graft.

Authors:  Jonathan Grinstein; Jeremy Estrada; Gabriel Sayer; Gene H Kim; Nitasha Sarswat; Sirtaz Adatya; Sandeep Nathan; Jonathan D Paul; John E A Blair; Valluvan Jeevanandam; Roberto Lang; Nir Uriel; Atman P Shah
Journal:  J Card Fail       Date:  2016-06-09       Impact factor: 5.712

Review 3.  Review and reflections about pulsatile ventricular assist devices from history to future: concerning safety and low haemolysis-still needed.

Authors:  Inge Köhne
Journal:  J Artif Organs       Date:  2020-05-04       Impact factor: 1.731