Literature DB >> 25628287

Does osteoporosis have a negative effect on the functional outcome of an osteoporotic distal radial fracture treated with a volar locking plate?

W-S Choi1, H J Lee2, D-Y Kim2, C-H Lee3, B G Lee2, J-H Kim4, K-H Lee2.   

Abstract

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score -3.16 (sd 0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score -1.72 (sd 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (sd 12.2) in group 1 and 10.5 (sd 13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (sd 14.04) in group 1 and 82.6 (sd 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson's correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient -0.26, p = 0.02). We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome. ©2015 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  distal radial fracture; osteoporosis; functional outcome; volar locking plate

Mesh:

Year:  2015        PMID: 25628287     DOI: 10.1302/0301-620X.97B2.34613

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  2 in total

1.  Factors Affecting Bone Mineral Density Measurement after Fracture in South Korea.

Authors:  Jin-Woo Kim; Yong-Chan Ha; Young-Kyun Lee
Journal:  J Bone Metab       Date:  2017-11-30

2.  Patient-related outcome, fracture displacement and bone mineral density following distal radius fracture in young and older men.

Authors:  Lisa Egund; Fiona E McGuigan; Niels Egund; Jack Besjakov; Kristina E Åkesson
Journal:  BMC Musculoskelet Disord       Date:  2020-12-07       Impact factor: 2.362

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.