Literature DB >> 25627131

Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model.

M Diana1, V Agnus, P Halvax, Y-Y Liu, B Dallemagne, A-I Schlagowski, B Geny, P Diemunsch, V Lindner, J Marescaux.   

Abstract

BACKGROUND: Fluorescence videography is a promising technique for assessing bowel perfusion. Fluorescence-based enhanced reality (FLER) is a novel concept, in which a dynamic perfusion cartogram, generated by computer analysis, is superimposed on to real-time laparoscopic images. The aim of this experimental study was to assess the accuracy of FLER in detecting differences in perfusion in a small bowel resection-anastomosis model.
METHODS: A small bowel ischaemic segment was created laparoscopically in 13 pigs. Animals were allocated to having anastomoses performed at either low perfusion (25 per cent; n = 7) or high perfusion (75 per cent; n = 6), as determined by FLER analysis. Capillary lactate levels were measured in blood samples obtained by serosal puncturing in the ischaemic area, resection lines and vascularized areas. Pathological inflammation scoring of the anastomosis was carried out.
RESULTS: Lactate levels in the ischaemic area (mean(s.d.) 5·6(2·8) mmol/l) were higher than those in resection lines at 25 per cent perfusion (3·7(1·7) mmol/l; P = 0·010) and 75 per cent perfusion (2·9(1·3) mmol/l; P < 0·001), and higher than levels in vascular zones (2·5(1·0) mmol/l; P < 0·001). Lactate levels in resection lines with 75 per cent perfusion were lower than those in lines with 25 per cent perfusion (P < 0·001), and similar to those in vascular zones (P = 0·188). Levels at resection lines with 25 per cent perfusion were higher than those in vascular zones (P = 0·001). Mean(s.d.) global inflammation scores were higher in the 25 per cent perfusion group compared with the 75 per cent perfusion group for mucosa/submucosa (2·1(0·4) versus 1·2(0·4); P = 0·003) and serosa (1·8(0·4) versus 0·8(0·8); P = 0·014). A ratio of preanastomotic lactate levels in the ischaemic area relative to the resection lines of 2 or less was predictive of a more severe inflammation score.
CONCLUSION: In an experimental model, FLER appeared accurate in discriminating bowel perfusion levels. Surgical relevance Clinical assessment has limited accuracy in evaluating bowel perfusion before anastomosis. Fluorescence videography estimates intestinal perfusion based on the fluorescence intensity of injected fluorophores, which is proportional to bowel vascularization. However, evaluation of fluorescence intensity remains a static and subjective measure. Fluorescence-based enhanced reality (FLER) is a dynamic fluorescence videography technique integrating near-infrared endoscopy and specific software. The software generates a virtual perfusion cartogram based on time to peak fluorescence, which can be superimposed on to real-time laparoscopic images. This experimental study demonstrates the accuracy of FLER in detecting differences in bowel perfusion in a survival model of laparoscopic small bowel resection-anastomosis, based on biochemical and histopathological data. It is concluded that real-time imaging of bowel perfusion is easy to use and accurate, and should be translated into clinical use.
© 2015 BJS Society Ltd. Published by John Wiley & Sons Ltd.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25627131     DOI: 10.1002/bjs.9725

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  43 in total

Review 1.  The quest for precision in transanal total mesorectal excision.

Authors:  A G Franchini Melani; M Diana; J Marescaux
Journal:  Tech Coloproctol       Date:  2015-11-26       Impact factor: 3.781

2.  Real-time fluorescence angiography by intra-arterial indocyanine green injection to identify obscure gastrointestinal bleeding territory: proof of concept in the porcine model.

Authors:  Yu-Yin Liu; Raoul Pop; Michele Diana; Seong-Ho Kong; Andras Lègner; Rémy Beaujeux; Jacques Marescaux
Journal:  Surg Endosc       Date:  2015-08-15       Impact factor: 4.584

Review 3.  [Fluorescence-guided detection of lymph node metastases of gastrointestinal tumors].

Authors:  Andrea Picchetto; Barbara Seeliger; Stefania La Rocca; Manuel Barberio; Giancarlo D'Ambrosio; Jacques Marescaux; Michele Diana
Journal:  Chirurg       Date:  2019-11       Impact factor: 0.955

4.  Quantitative perfusion assessment of intestinal anastomoses in pigs treated with glucagon-like peptide 2.

Authors:  Nikolaj Nerup; Linea Landgrebe Ring; Rune Broni Strandby; Charlotte Egeland; Morten Bo Søndergaard Svendsen; Jane Preuss Hasselby; Gro Linno Willemoe; Bolette Hartmann; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2018-10-18       Impact factor: 3.445

5.  Evaluation of hyperspectral imaging (HSI) for the measurement of ischemic conditioning effects of the gastric conduit during esophagectomy.

Authors:  Hannes Köhler; Boris Jansen-Winkeln; Marianne Maktabi; Manuel Barberio; Jonathan Takoh; Nico Holfert; Yusef Moulla; Stefan Niebisch; Michele Diana; Thomas Neumuth; Sebastian M Rabe; Claire Chalopin; Andreas Melzer; Ines Gockel
Journal:  Surg Endosc       Date:  2019-01-23       Impact factor: 4.584

6.  Fluorescence lymphangiography-guided full-thickness oncologic gastric resection.

Authors:  Seong-Ho Kong; Francesco Marchegiani; Renato Soares; Yu-Yin Liu; Yun-Suhk Suh; Hyuk-Joon Lee; Bernard Dallemagne; Han-Kwang Yang; Jacques Marescaux; Michele Diana
Journal:  Surg Endosc       Date:  2018-08-27       Impact factor: 4.584

7.  Visualization and quantification of anastomotic perfusion in colorectal surgery using near-infrared fluorescence.

Authors:  S Hayami; K Matsuda; H Iwamoto; M Ueno; M Kawai; S Hirono; K Okada; M Miyazawa; K Tamura; Y Mitani; Y Kitahata; Y Mizumoto; Hiroki Yamaue
Journal:  Tech Coloproctol       Date:  2019-09-18       Impact factor: 3.781

8.  Precision real-time evaluation of bowel perfusion: accuracy of confocal endomicroscopy assessment of stoma in a controlled hemorrhagic shock model.

Authors:  Michele Diana; Eric Noll; Anne-Laure Charles; Pierre Diemunsch; Bernard Geny; Yu-Yin Liu; Francesco Marchegiani; Luigi Schiraldi; Vincent Agnus; Veronique Lindner; Lee Swanström; Bernard Dallemagne; Jacques Marescaux
Journal:  Surg Endosc       Date:  2016-06-20       Impact factor: 4.584

9.  Feasibility of real-time intestinal bloodstream evaluation using probe-based confocal laser endomicroscopy in a porcine intestinal ischemia model.

Authors:  Tsuyoshi Takahashi; Rie Nakatsuka; Hisashi Hara; Shigeyoshi Higashi; Kouji Tanaka; Yasuhiro Miyazaki; Tomoki Makino; Yukinori Kurokawa; Makoto Yamasaki; Shuji Takiguchi; Masaki Mori; Yuichiro Doki; Kiyokazu Nakajima
Journal:  Surg Endosc       Date:  2017-10-24       Impact factor: 4.584

10.  Laser speckle contrast imaging and quantitative fluorescence angiography for perfusion assessment.

Authors:  Jonas Hedelund Rønn; Nikolaj Nerup; Rune Broni Strandby; Morten Bo Søndergaard Svendsen; Rikard Ambrus; Lars Bo Svendsen; Michael Patrick Achiam
Journal:  Langenbecks Arch Surg       Date:  2019-05-04       Impact factor: 3.445

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.