Literature DB >> 25626855

Multifocal versus monofocal intraocular lenses after cataract extraction.

Daniel Calladine, Jennifer R Evans, Sweata Shah, Martin Leyland.   

Abstract

BACKGROUND: Good unaided distance visual acuity is now a realistic expectation following cataract surgery and intraocular lens (IOL) implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal) IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs.
OBJECTIVES: The objective of this review was to assess the effects of multifocal IOLs, including effects on visual acuity, subjective visual satisfaction, spectacle dependence, glare and contrast sensitivity, compared to standard monofocal lenses in people undergoing cataract surgery. SEARCH
METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register), The Cochrane Library 2012, Issue 2, MEDLINE (January 1946 to March 2012), EMBASE (January 1980 to March 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 6 March 2012. We searched the reference lists of relevant articles and contacted investigators of included studies and manufacturers of multifocal IOLs for information about additional published and unpublished studies. SELECTION CRITERIA: All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. DATA COLLECTION AND ANALYSIS: Two authors collected data and assessed trial quality. Where possible, we pooled data from the individual studies using a random-effects model, otherwise we tabulated data. MAIN
RESULTS: Sixteen completed trials (1608 participants) and two ongoing trials were identified. All included trials compared multifocal and monofocal lenses but there was considerable variety in the make and model of lenses implanted. Overall we considered the trials at risk of performance and detection bias because it was difficult to mask patients and outcome assessors. It was also difficult to assess the role of reporting bias. There was moderate quality evidence that similar distance acuity is achieved with both types of lenses (pooled risk ratio, RR for unaided visual acuity worse than 6/6: 0.98, 95% confidence interval, CI 0.91 to 1.05). There was also evidence that people with multifocal lenses had better near vision but methodological and statistical heterogeneity meant that we did not calculate a pooled estimate for effect on near vision. Total freedom from use of glasses was achieved more frequently with multifocal than monofocal IOLs. Adverse subjective visual phenomena, particularly haloes, or rings around lights, were more prevalent and more troublesome in participants with the multifocal IOL and there was evidence of reduced contrast sensitivity with the multifocal lenses.

Entities:  

Mesh:

Year:  2015        PMID: 25626855     DOI: 10.1590/1516-3180.20151331T2

Source DB:  PubMed          Journal:  Sao Paulo Med J        ISSN: 1516-3180            Impact factor:   1.044


  13 in total

1.  [Optical quality of three trifocal intraocular lens models : An optical bench comparison].

Authors:  R Khoramnia; T M Yildirim; T Tandogan; S Liebing; G Łabuz; C Y Choi; G Auffarth
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

2.  Development of a Reading Accessibility Index Using the MNREAD Acuity Chart.

Authors:  Aurélie Calabrèse; Cynthia Owsley; Gerald McGwin; Gordon E Legge
Journal:  JAMA Ophthalmol       Date:  2016-04       Impact factor: 7.389

3.  Reversibility of the duet procedure: Bilateral exchange of a supplementary trifocal sulcus-fixated intraocular lens for correction of a postoperative refractive error.

Authors:  Isabella Diana Baur; Gerd Uwe Auffarth; Timur Mert Yildirim; Christian Steffen Mayer; Ramin Khoramnia
Journal:  Am J Ophthalmol Case Rep       Date:  2020-10-10

4.  Comparison between bilateral implantation of a trifocal intraocular lens (Alcon Acrysof IQ® PanOptix) and extended depth of focus lens (Tecnis® Symfony® ZXR00 lens).

Authors:  Mohsen Farvardin; Mohammadkarim Johari; Adel Attarzade; Feisal Rahat; Reza Farvardin; Zahra Farvardin
Journal:  Int Ophthalmol       Date:  2020-10-10       Impact factor: 2.031

5.  Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF).

Authors:  Banu Torun Acar; Erkan Duman; Saban Simsek
Journal:  BMC Ophthalmol       Date:  2016-11-29       Impact factor: 2.209

6.  Unilateral implantation of a new non-diffractive extended range-of-vision IOL in a young patient with Curschmann-Steinert myotonic dystrophy.

Authors:  Isabella Baur; Gerd U Auffarth; Grzegorz Łabuz; Ramin Khoramnia
Journal:  Am J Ophthalmol Case Rep       Date:  2021-04-17

Review 7.  Patient considerations in cataract surgery - the role of combined therapy using phenylephrine and ketorolac.

Authors:  Roberto Gonzalez-Salinas; Adriano Guarnieri; María Concepción Guirao Navarro; Manuel Saenz-de-Viteri
Journal:  Patient Prefer Adherence       Date:  2016-09-15       Impact factor: 2.711

8.  Trifocal versus Bifocal Diffractive Intraocular Lens Implantation after Cataract Surgery or Refractive Lens Exchange: a Meta-analysis.

Authors:  Chang Ho Yoon; In-Soo Shin; Mee Kum Kim
Journal:  J Korean Med Sci       Date:  2018-09-27       Impact factor: 2.153

9.  Effect of incision on visual outcomes after implantation of a trifocal diffractive IOL.

Authors:  Shasha Xue; Guiqiu Zhao; Xiaoni Yin; Jing Lin; Cui Li; Liting Hu; Lin Leng; Xuejiao Yang
Journal:  BMC Ophthalmol       Date:  2018-07-13       Impact factor: 2.209

10.  Visual Performances of a New Extended Depth-of-Focus Intraocular Lens with a Refractive Design: A Prospective Study After Bilateral Implantation.

Authors:  Leopoldo Spadea; Maria Ilaria Giannico; Martina Formisano; Ludovico Alisi
Journal:  Ther Clin Risk Manag       Date:  2021-07-16       Impact factor: 2.423

View more