Literature DB >> 25625136

Effect of salivary contamination and decontamination on bond strength of two one-step self-etching adhesives to dentin of primary and permanent teeth.

Katharina Santschi, Anne Peutzfeldt, Adrian Lussi, Simon Flury.   

Abstract

PURPOSE: To evaluate the effects of human saliva contamination and two decontamination procedures at different stages of the bonding procedure on the bond strength of two one-step self-etching adhesives to primary and permanent dentin.
MATERIALS AND METHODS: Extracted human primary and permanent molars (210 of each) were ground to mid-coronal dentin. The dentin specimens were randomly divided into 7 groups (n = 15/group/molar type) for each adhesive (Xeno V+ and Scotchbond Universal): no saliva contamination (control); saliva contamination before or after light curing of the adhesives followed by air drying, rinsing with water spray/air drying, or by rinsing with water spray/air drying/reapplication of the adhesives. Resin composite (Filtek Z250) was applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests.
RESULTS: Xeno V+ generated significantly higher SBS than Scotchbond Universal when no saliva contamination occurred. Saliva contamination reduced SBS of Xeno V+, with the reduction being more pronounced when contamination occurred before light curing than after. In both situations, decontamination involving reapplication of the adhesive restored SBS. Saliva contamination had no significant effect on Scotchbond Universal. There were no differences in SBS between primary and permanent teeth.
CONCLUSION: Rinsing with water and air drying followed by reapplication of the adhesive restored bond strength to saliva-contaminated dentin.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25625136     DOI: 10.3290/j.jad.a33514

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  7 in total

1.  The effect of different liners on the bond strength of a compomer to primary teeth dentine: in vitro study.

Authors:  R Frankenberger; S Nassiri; S Lücker; N N Lygidakis; N Krämer
Journal:  Eur Arch Paediatr Dent       Date:  2021-02-03

2.  [Effects of three self-etch adhesives and mild salivary contamination on the bonding durability of deciduous teeth].

Authors:  C Y Luo; C F Peng; Y Yang; M Qin; Y Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-09

3.  Exposed Dentin: Influence of Cleaning Procedures and Simulated Pulpal Pressure on Bond Strength of a Universal Adhesive System.

Authors:  Simon Flury; Anne Peutzfeldt; Patrick R Schmidlin; Adrian Lussi
Journal:  PLoS One       Date:  2017-01-12       Impact factor: 3.240

4.  Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

Authors:  Mahtab Memarpour; Fereshteh Shafiei; Mehran Zarean; Faranak Razmjoei
Journal:  J Clin Exp Dent       Date:  2018-01-01

5.  Shear bond strength and scanning electron microscopy characteristics of universal adhesive in primary tooth dentin: An in vitro study.

Authors:  Mahtab Memarpour; Fereshteh Shafiei; Faranak Razmjouei; Mina Soltani
Journal:  Dent Res J (Isfahan)       Date:  2018 Jul-Aug

6.  New Dual-cure Resin-based Material in Occlusal and Occluso-proximal Restorations of Primary Teeth: Results of a Randomized Clinical Trial.

Authors:  Cinthia Maria Baggio de Luca da Cunha; Letícia Maíra Wambier; Thalita de Paris Matos; Pamela Malaquias; Alessandra Reis; Alessandro Dourado Loguercio; Denise Stadler Wambier; Ana Cláudia Rodrigues Chibinski
Journal:  Int J Clin Pediatr Dent       Date:  2022 Jan-Feb

7.  The long-term consequence of salivary contamination at various stages of adhesive application and clinically feasible remedies to decontaminate.

Authors:  Pooja Nair; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2020-06-09       Impact factor: 3.573

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.