Mechanical degradation of biological heart valve tissue induced by low diameter crimping: an early assessment.

Foued Khoffi1, Frederic Heim2.   

Abstract

Transcatheter aortic valve implantation (TAVI) has become today an increasingly attractive procedure to relieve patients from aortic valve disease. However, the procedure requires crimping biological tissue within a metallic stent for low diameter catheter insertion purpose. This step induces specific stress in the leaflets especially when the crimping diameter is small. One concern about crimping is the potential degradations undergone by the biological tissue, which may limit the durability of the valve once implanted. The purpose of the present work is to study the effect of low diameter crimping on the mechanical performances of pericardium valve prototypes. The prototypes were compressed to a diameter of 1mm within braided stents for 20 min. SEM observations performed on crimped material show that crimped leaflets undergo degradations characterized by apparent surface defects. Moreover mechanical extension tests were performed on pericardium strips before and after crimping. The strips (15 mm long, 5mm wide) were taken from both crimped and native leaflets considering 2 different valve diameters, 19 and 21 mm. In order to prevent the premature drying of the pericardium tissue during the procedure, the biological tissue was kept in contact with a formaldehyde solution. Results show that the ultimate strength value decreases nearly by up to 50%. The modifications observed in the material may jeopardize the long term durability of the device. However, further tests are necessary with a larger amount of samples to confirm these early results.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Crimping; Heart valve; Pericardium leaflets; Transcatheter

Mesh:

Year:  2015        PMID: 25621851     DOI: 10.1016/j.jmbbm.2015.01.005

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  6 in total

Review 1.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

2.  In Vitro Durability and Stability Testing of a Novel Polymeric Transcatheter Aortic Valve.

Authors:  Oren M Rotman; Brandon Kovarovic; Matteo Bianchi; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2020-02       Impact factor: 3.826

3.  In Vitro Hydrodynamic Assessment of a New Transcatheter Heart Valve Concept (the TRISKELE).

Authors:  Benyamin Rahmani; Spyros Tzamtzis; Rose Sheridan; Michael J Mullen; John Yap; Alexander M Seifalian; Gaetano Burriesci
Journal:  J Cardiovasc Transl Res       Date:  2016-12-27       Impact factor: 4.132

4.  The study of dry biological valve crosslinked with a combination of carbodiimide and polyphenol.

Authors:  Li Yang; Shuang Xie; Kailei Ding; Yang Lei; Yunbing Wang
Journal:  Regen Biomater       Date:  2020-12-03

5.  Design Variation, Implantation, and Outcome of Transcatheter Mitral Valve Prosthesis: A Comprehensive Review.

Authors:  Faizus Sazzad; Jimmy Kim Fatt Hon; Kollengode Ramanathan; Jie Hui Nah; Zhi Xian Ong; Lian Kah Ti; Roger Foo; Edgar Tay; Theo Kofidis
Journal:  Front Cardiovasc Med       Date:  2022-02-24

6.  Commentary: Leaflet perforation after transcatheter aortic valve implantation in calcified roots: When perfect can be the enemy of good?

Authors:  Aleksander Dokollari; Gianluigi Bisleri
Journal:  JTCVS Tech       Date:  2020-06-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.