Quantitative assessment of liver fibrosis by digital image analysis: Relationship to Ishak staging and elasticity by shear-wave elastography.

Ender Gunes Yegin1, Korkut Yegin, Emrah Karatay, Erdem Faruk Kombak, Davut Tuney, Cigdem Ataizi-Celikel, Osman Cavit Ozdogan.   

Abstract

OBJECTIVE: To analyze the relationship between fibrosis staged by Ishak stage and quantified by digital image analysis (DIA), and to reveal the optimum performance of shear-wave elastography (SWE) using quantitative DIA measurements as a comparative histological standard.
METHODS: The proportionate area (PA) of fibrosis was measured by DIA from images of the PA of trichrome-stain (TPA) of 168 chronic hepatitis patients. SWE was performed in 105 patients. The accuracy of SWE for predicting the fibrosis defined by quantitative PA thresholds (≥ 2.5%, ≥ 5%, ≥ 10% and ≥ 20%, respectively) and by Ishak stages was measured using the area under the receiver operating characteristic curve (AUROC).
RESULTS: DIA was proven to be highly reproducible (interclass correlation coefficient  0.926). The TPA range corresponding to each Ishak stage was large, widened as stages progressed, and reached its greatest extent in cirrhosis. TPA magnified at ×50 ranges 11.9-56% for Ishak stage F5-6. A good correlation between TPA and elasticity was presented for more advanced fibrosis (TPA ≥10%, rs  = 0.732, P = 0.000) than milder fibrosis (TPA <10%, rs  = 0.308, P = 0.006). With the advance of fibrosis either by stages or PA thresholds the discriminative accuracy of SWE gradually increased, but was less satisfactory for milder fibrosis.
CONCLUSIONS: DIA may serve as a reproducible and reliable quantitative standard for surrogate tests for liver fibrosis. The performance and correlation of SWE with the fibrotic extent were better for advanced fibrosis, but less satisfactory for milder fibrosis.
© 2015 Chinese Medical Association Shanghai Branch, Chinese Society of Gastroenterology, Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

Entities:  

Keywords:  diagnostic performance; digital image analysis; fibrosis; histopathological staging; liver cirrhosis; proportionate area; shear-wave elastography

Mesh:

Substances:

Year:  2015        PMID: 25620218     DOI: 10.1111/1751-2980.12231

Source DB:  PubMed          Journal:  J Dig Dis        ISSN: 1751-2972            Impact factor:   2.325


  2 in total

1.  Evaluation of Peritumoral Fibrosis in Metastatic Colorectal Adenocarcinoma to the Liver Using Digital Image Analysis.

Authors:  Kevin M Waters; Tricia R Cottrell; Sepideh Besharati; Qingfeng Zhu; Robert A Anders
Journal:  Am J Clin Pathol       Date:  2019-01-07       Impact factor: 2.493

2.  Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis.

Authors:  Juan Fu; Biao Wu; Huazhi Wu; Feng Lin; Wei Deng
Journal:  BMC Med Imaging       Date:  2020-02-11       Impact factor: 1.930

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.