Literature DB >> 25620191

Impact of coronary artery stent edge dissections on long-term clinical outcome in patients with acute coronary syndrome: an optical coherence tomography study.

Konstantina P Bouki1, Eleni Sakkali1, Konstantinos Toutouzas2, Delia Vlad1, Dimitrios Barmperis1, Stavroula Phychari1, Maria Riga2, Thomas Apostolou2, Christodoulos Stefanadis2.   

Abstract

AIMS: The purpose of the present study was to assess the incidence, predictors and long term prognosis of stent edge dissections identified by (OCT) after the implantation of bare metal (BMS) and drug eluting stents (DES). METHODS AND
RESULTS: We studied 74 patients who underwent percutaneous coronary intervention (PCI) because of an acute coronary syndrome. Edge dissections were found in 29 of 74 patients (39.1%). Independent predictors of edge dissections were: the presence of ST-elevation myocardial infarction (STEMI) (P = 0.005, odds ratio 11.78; 95% Cl 2.06-67.10), the small reference lumen diameter (P = 0.009, odds ratio 0.11; 95% Cl 0.02-0.58) and the short stents implanted (P = 0.013, odds ratio 0.83; 95% Cl 0.72-0.96). During a follow-up period of 25.6 ± 9.4 months 11 patients presented with at least one major adverse cardiac event. Event free survival was significantly decreased in patients with edge dissection with a flap thickness >0.31 mm compared to patients with thinner flap or without any dissection (P < 0.001).
CONCLUSIONS: OCT frequently detects edge dissections, usually related to STEMI presentation and to PCI technique. Deep vessel wall injury at stent edges with a dissection flap thickness more than 0.31mm carries an adverse clinical impact on long-term clinical outcome.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  acute coronary syndrome; clinical outcome; optical coherence tomography; stent edge dissection

Mesh:

Year:  2015        PMID: 25620191     DOI: 10.1002/ccd.25855

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  8 in total

Review 1.  [Coronary interventions : Current developments for improved long-term results].

Authors:  T Seidler
Journal:  Internist (Berl)       Date:  2016-09       Impact factor: 0.743

2.  Black-pooling sign: A novel intravascular ultrasound imaging marker that predicts stent edge hematoma growth.

Authors:  Yusuke Oba; Hiroshi Funayama; Hayato Shimizu; Masao Takahashi; Kazuomi Kario
Journal:  Anatol J Cardiol       Date:  2021-04       Impact factor: 1.596

3.  CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) in 2018.

Authors:  Yukio Ozaki; Yuki Katagiri; Yoshinobu Onuma; Tetsuya Amano; Takashi Muramatsu; Ken Kozuma; Satoru Otsuji; Takafumi Ueno; Nobuo Shiode; Kazuya Kawai; Nobuhiro Tanaka; Kinzo Ueda; Takashi Akasaka; Keiichi Igarashi Hanaoka; Shiro Uemura; Hirotaka Oda; Yoshiaki Katahira; Kazushige Kadota; Eisho Kyo; Katsuhiko Sato; Tadaya Sato; Junya Shite; Koichi Nakao; Masami Nishino; Yutaka Hikichi; Junko Honye; Tetsuo Matsubara; Sumio Mizuno; Toshiya Muramatsu; Taku Inohara; Shun Kohsaka; Ichiro Michishita; Hiroyoshi Yokoi; Patrick W Serruys; Yuji Ikari; Masato Nakamura
Journal:  Cardiovasc Interv Ther       Date:  2018-03-29

Review 4.  CVIT expert consensus document on primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI) update 2022.

Authors:  Yukio Ozaki; Hironori Hara; Yoshinobu Onuma; Yuki Katagiri; Tetsuya Amano; Yoshio Kobayashi; Takashi Muramatsu; Hideki Ishii; Ken Kozuma; Nobuhiro Tanaka; Hitoshi Matsuo; Shiro Uemura; Kazushige Kadota; Yutaka Hikichi; Kenichi Tsujita; Junya Ako; Yoshihisa Nakagawa; Yoshihiro Morino; Ichiro Hamanaka; Nobuo Shiode; Junya Shite; Junko Honye; Tetsuo Matsubara; Kazuya Kawai; Yasumi Igarashi; Atsunori Okamura; Takayuki Ogawa; Yoshisato Shibata; Takafumi Tsuji; Junji Yajima; Kaoru Iwabuchi; Nobuo Komatsu; Teruyasu Sugano; Masaru Yamaki; Shinichiro Yamada; Hiroaki Hirase; Yuusuke Miyashita; Fuminobu Yoshimachi; Masakazu Kobayashi; Jiro Aoki; Hirotaka Oda; Yoshiaki Katahira; Kinzo Ueda; Masami Nishino; Koichi Nakao; Ichiro Michishita; Takafumi Ueno; Taku Inohara; Shun Kohsaka; Tevfik F Ismail; Patrick W Serruys; Masato Nakamura; Hiroyoshi Yokoi; Yuji Ikari
Journal:  Cardiovasc Interv Ther       Date:  2022-01-12

5.  Impact of stent edge dissection detected by optical coherence tomography after current-generation drug-eluting stent implantation.

Authors:  Hiroyuki Jinnouchi; Kenichi Sakakura; Tomonobu Yanase; Yusuke Ugata; Takunori Tsukui; Yosuke Taniguchi; Kei Yamamoto; Masaru Seguchi; Hiroshi Wada; Hideo Fujita
Journal:  PLoS One       Date:  2021-11-04       Impact factor: 3.240

Review 6.  Intravascular imaging in coronary stent restenosis: Prevention, characterization, and management.

Authors:  Amr Abouelnour; Tommaso Gori
Journal:  Front Cardiovasc Med       Date:  2022-08-09

7.  Dissections after bioresorbable vascular scaffold implantation in the POLAR ACS Registry.

Authors:  Wojciech Zasada; Artur Dziewierz; Lukasz Partyka; Michal Wegiel; Beata Bobrowska; Rafal Depukat; Tomasz Rakowski; Dariusz Dudek; Stanislaw Bartus; Lukasz Rzeszutko
Journal:  Postepy Kardiol Interwencyjnej       Date:  2022-08-19       Impact factor: 1.065

8.  Comparison Between Optical Frequency Domain Imaging and Intravascular Ultrasound for Percutaneous Coronary Intervention Guidance in Biolimus A9-Eluting Stent Implantation: A Randomized MISTIC-1 Non-Inferiority Trial.

Authors:  Takashi Muramatsu; Yukio Ozaki; Mamoru Nanasato; Masato Ishikawa; Ryo Nagasaka; Masaya Ohota; Yosuke Hashimoto; Yu Yoshiki; Hidemaro Takatsu; Katsuyoshi Ito; Hiroki Kamiya; Yukihiko Yoshida; Toyoaki Murohara; Hideo Izawa
Journal:  Circ Cardiovasc Interv       Date:  2020-10-27       Impact factor: 6.546

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.