Literature DB >> 25619481

DEVELOPING A TECHNIQUE FOR ULTRASOUND-GUIDED INJECTION OF THE ADULT CANINE HIP.

Chiara Bergamino1, Anne-Laure Etienne2, Valeria Busoni3.   

Abstract

An accurate method for guiding injections into the canine hip would facilitate diagnostic localization of lameness and targeted treatments. Ultrasound-guided hip injections are commonly used in humans and large animals. Aims of this prospective study were to describe ultrasound (US) anatomy of the adult canine hip and determine the feasibility and accuracy of intra-articular placement of injectate using US-guidance. Seven adult dogs were used to describe US anatomy, five dog cadavers were used to assess the feasibility of the injection technique and 11 dog cadavers were used to assess accuracy of injections. For the accuracy test, 22 joints were injected with iodinated contrast medium by three operators with different experience. With dogs in lateral recumbency, the hyperechoic femoral head surface was identified by following the femoral neck from the greater trochanter or the acetabular rim was localized by following caudally the ilium from the iliac wing. An anechoic gap between the femoral head and acetabular surface represented the joint. The capsule was visible as a triangular echoic structure and the femoral head articular cartilage appeared as an anechoic band. The needle was inserted axial to the greater trochanter and directed in a dorsolateral-ventromedial direction toward the joint space and then pushed through the capsule. Based on postinjection radiography, accuracy was 81.8% at first attempt and 100% at second attempt. This study indicated that US-guided injection is a feasible and accurate technique for injecting the adult canine hip. Future studies in live dogs are needed to assess safety and efficacy.
© 2015 American College of Veterinary Radiology.

Entities:  

Keywords:  anatomy; dog; hip; injection; ultrasound

Mesh:

Substances:

Year:  2015        PMID: 25619481     DOI: 10.1111/vru.12242

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  2 in total

1.  Accuracy of Ultrasound-Guided versus Landmark-Guided Intra-articular Injection for Rat Knee Joints.

Authors:  Amparo Ruiz; Dalibel Bravo; Alejandra Duarte; Ronald S Adler; José G Raya
Journal:  Ultrasound Med Biol       Date:  2019-07-19       Impact factor: 2.998

2.  Transcutaneous Ultrasound Guided Intraovarian Injection in Rats (Rattus norvegicus).

Authors:  Etiele M Gomes; Endreo A P Dos Santos; Leonel F L Neto; Danielle R Padilha; Gabrielle C S Campos; Roberto Thiesen; Ingrid R L Machado; Maria Ligia A Mestieri
Journal:  J Am Assoc Lab Anim Sci       Date:  2021-07-19       Impact factor: 1.232

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.