Literature DB >> 25616989

Simultaneous quantification of related substances of perindopril tert-butylamine using a novel stability indicating liquid chromatographic method.

Zoltán-István Szabó1, Zenkő-Zsuzsánna Réti2, László Gagyi2, Erika Lilla Kis2, Emese Sipos3.   

Abstract

A novel stability indicating gradient reverse-phased high-performance liquid chromatographic method has been developed for the quantification of impurities of perindopril tert-butylamine (PER) in pharmaceutical dosage form. Separation of the active substance and its known (Impurities B, C, D, E, F) and unknown impurities was achieved on a BDS Hypersil C18 column (250 mm × 4.6 mm, 5 µm), thermostated at 70°C, using a mobile phase comprised of aqueous solution of sodium 1-heptanesulfonate adjusted to pH 2 with perchloric acid and acetonitrile. The flow rate was maintained at 1.5 mL min(-1), injection volume of 20 µL was utilized and detection of analytes was performed at 215 nm. The developed method was validated in accordance with current ICH Guidelines for all suggested parameters, including forced degradation studies and proved to be linear, accurate, precise and suitable for the impurity testing of PER, being subsequently applied during on-going stability studies of a newly developed generic formulation.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25616989     DOI: 10.1093/chromsci/bmu223

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618