Literature DB >> 25616968

Vortex-assisted magnetic β-cyclodextrin/attapulgite-linked ionic liquid dispersive liquid-liquid microextraction coupled with high-performance liquid chromatography for the fast determination of four fungicides in water samples.

Miyi Yang1, Xuefei Xi1, Xiaoling Wu1, Runhua Lu1, Wenfeng Zhou1, Sanbing Zhang1, Haixiang Gao2.   

Abstract

A novel microextraction technique combining magnetic solid-phase microextraction (MSPME) with ionic liquid dispersive liquid-liquid microextraction (IL-DLLME) to determine four fungicides is presented in this work for the first time. The main factors affecting the extraction efficiency were optimized by the one-factor-at-a-time approach and the impacts of these factors were studied by an orthogonal design. Without tedious clean-up procedure, analytes were extracted from the sample to the adsorbent and organic solvent and then desorbed in acetonitrile prior to chromatographic analysis. Under the optimum conditions, good linearity and high enrichment factors were obtained for all analytes, with correlation coefficients ranging from 0.9998 to 1.0000 and enrichment factors ranging 135 and 159 folds. The recoveries for proposed approach were between 98% and 115%, the limits of detection were between 0.02 and 0.04 μg L(-1) and the RSDs changed from 2.96 to 4.16. The method was successfully applied in the analysis of four fungicides (azoxystrobin, chlorothalonil, cyprodinil and trifloxystrobin) in environmental water samples. The recoveries for the real water samples ranged between 81% and 109%. The procedure proved to be a time-saving, environmentally friendly, and efficient analytical technique.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Attapulgite; Dispersive liquid–liquid microextraction; Fungicide; High performance liquid chromatography; Ionic liquid; Magnetic

Mesh:

Substances:

Year:  2015        PMID: 25616968     DOI: 10.1016/j.chroma.2015.01.016

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  β-Cyclodextrin Assisted Liquid-Liquid Microextraction Based on Solidification of the Floating Organic Droplets Method for Determination of Neonicotinoid Residues.

Authors:  Jitlada Vichapong; Khwankaew Moyakao; Rawikan Kachangoon; Rodjana Burakham; Yanawath Santaladchaiyakit; Supalax Srijaranai
Journal:  Molecules       Date:  2019-10-31       Impact factor: 4.411

2.  [Recent developments of pesticide adsorbents based on cyclodextrins].

Authors:  Jinfeng Zhang; Ping Li; Jiutong Ma; Qiong Jia
Journal:  Se Pu       Date:  2021-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.