Literature DB >> 25616587

The role of inferior vena cava diameter in volume status monitoring; the best sonographic measurement method?

Nalan Gökçe Çelebi Yamanoğlu1, Adnan Yamanoğlu2, İsmet Parlak3, Pelin Pınar3, Ali Tosun4, Burak Erkuran3, Gizem Aydınok3, Fatih Torlak5.   

Abstract

OBJECTIVES: This study aims to determine the site of and the best sonographic method for measurement of inferior vena cava (IVC) diameter in volume status monitoring.
METHODS: This observational before-and-after study was performed at the intensive care unit of the emergency department. It included hypotensive adult patients with suspected sepsis who were recommended to receive at least 20 mg/kg fluid replacement by the emergency physician. The patients were fluid replaced at a rate of 1000 mL/h, and maximum and minimum IVC diameters were measured and the Caval index calculated sonographically via both B-mode and M-mode. Hence, IVC's volume response was assessed by a total of 6 parameters, 3 each in M-mode and B-mode. Freidman test was used to assess the change in IVC diameter with fluid replacement. Wilcoxon test with Bonferroni correction was used to determine which measurement method more sensitively measured IVC diameter change.
RESULTS: Twenty-eight patients with a mean age of 71.3 were included in the final analysis.The IVC diameter change was significant with all 6 methods (P < .001). The IVC minimum diameter change measured on M-mode during inspiration (M-mode i) was the only measurement method that significantly showed diameter change with each 500-mL fluid replacements. The initial and the subsequent M-mode i values after each 500 mL of fluid were 5.65 ± 3.34; 8.05 ± 3.66; 10.16 ± 3.61, and 11.21 ± 2.94, respectively (P < .001, P < .002, and P < .003, respectively).
CONCLUSION: Inferior vena cava diameter was changed by fluid administration. The M-mode i method that most sensitively measures that change may be the most successful method in volume status monitoring.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25616587     DOI: 10.1016/j.ajem.2014.12.014

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  3 in total

1.  Competence of Intensivists in Focused Transthoracic Echocardiography in Intensive Care Unit: A Prospective Observational Study.

Authors:  Muthapillai Senthilnathan; Pankaj Kundra; Sandeep Kumar Mishra; Savitri Velayudhan; Ajith Ananthakrishna Pillai
Journal:  Indian J Crit Care Med       Date:  2018-05

2.  Inferior Vena Cava Measurement with Ultrasound: What Is the Best View and Best Mode?

Authors:  Nathan M Finnerty; Ashish R Panchal; Creagh Boulger; Amar Vira; Jason J Bischof; Christopher Amick; David P Way; David P Bahner
Journal:  West J Emerg Med       Date:  2017-02-24

3.  Sonographic Assessment of Intravascular Fluid Estimate (SAFE) Score by Using Bedside Ultrasound in the Intensive Care Unit.

Authors:  Keith Killu; Victor Coba; Dionne Blyden; Semeret Munie; Darlene Dereczyk; Pridvi Kandagatla; Amy Tang
Journal:  Crit Care Res Pract       Date:  2020-02-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.