Literature DB >> 25615261

FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties.

Y De Deene1, P S Skyt, R Hil, J T Booth.   

Abstract

Three dimensional radiation dosimetry has received growing interest with the implementation of highly conformal radiotherapy treatments. The radiotherapy community faces new challenges with the commissioning of image guided and image gated radiotherapy treatments (IGRT) and deformable image registration software.A new three dimensional anthropomorphically shaped flexible dosimeter, further called 'FlexyDos3D', has been constructed and a new fast optical scanning method has been implemented that enables scanning of irregular shaped dosimeters. The FlexyDos3D phantom can be actuated and deformed during the actual treatment. FlexyDos3D offers the additional advantage that it is easy to fabricate, is non-toxic and can be molded in an arbitrary shape with high geometrical precision.The dosimeter formulation has been optimized in terms of dose sensitivity. The influence of the casting material and oxygen concentration has also been investigated. The radiophysical properties of this new dosimeter are discussed including stability, spatial integrity, temperature dependence of the dosimeter during radiation, readout and storage, dose rate dependence and tissue equivalence.

Entities:  

Mesh:

Year:  2015        PMID: 25615261     DOI: 10.1088/0031-9155/60/4/1543

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Radiological tissue equivalence of deformable silicone-based chemical radiation dosimeters (FlexyDos3D).

Authors:  Yi Du; Ruoxi Wang; Meijiao Wang; Haizhen Yue; Yibao Zhang; Hao Wu; Weihu Wang
Journal:  J Appl Clin Med Phys       Date:  2019-06-11       Impact factor: 2.102

Review 2.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

3.  Basic Properties of a New Polymer Gel for 3D-Dosimetry at High Dose-Rates Typical for FFF Irradiation Based on Dithiothreitol and Methacrylic Acid (MAGADIT): Sensitivity, Range, Reproducibility, Accuracy, Dose Rate Effect and Impact of Oxygen Scavenger.

Authors:  Muzafar Khan; Gerd Heilemann; Wolfgang Lechner; Dietmar Georg; Andreas Georg Berg
Journal:  Polymers (Basel)       Date:  2019-10-19       Impact factor: 4.329

4.  Dose response of three-dimensional silicone-based radiochromic dosimeters for photon irradiation in the presence of a magnetic field.

Authors:  Morten B Jensen; Peter Balling; Simon J Doran; Jørgen B B Petersen; Isak H Wahlstedt; Ludvig P Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-10-19

5.  Dose-response of deformable radiochromic dosimeters for spot scanning proton therapy.

Authors:  Simon V Jensen; Lia B Valdetaro; Per R Poulsen; Peter Balling; Jørgen B B Petersen; Ludvig P Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2020-11-20

6.  Features of PABIGnx 3D Polymer Gel as an Ionising Radiation Dosimeter.

Authors:  Marek Kozicki; Malwina Jaszczak; Piotr Maras
Journal:  Materials (Basel)       Date:  2022-03-31       Impact factor: 3.623

Review 7.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

8.  Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy.

Authors:  Piotr Maras; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

9.  Empirical quenching correction in radiochromic silicone-based three-dimensional dosimetry of spot-scanning proton therapy.

Authors:  Lia Barbosa Valdetaro; Ellen Marie Høye; Peter Sandegaard Skyt; Jørgen Breede Baltzer Petersen; Peter Balling; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2021-04-12

10.  Performance variations among clinically available deformable image registration tools in adaptive radiotherapy - how should we evaluate and interpret the result?

Authors:  Ke Nie; Jean Pouliot; Eric Smith; Cynthia Chuang
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.