Literature DB >> 25613649

Laboratory blood analysis in Strigiformes-Part II: plasma biochemistry reference intervals and agreement between the Abaxis Vetscan V2 and the Roche Cobas c501.

Mélanie Ammersbach1, Hugues Beaufrère, Annick Gionet Rollick, Thomas Tully.   

Abstract

BACKGROUND: Limited plasma biochemical information is available in Strigiformes. Only one study investigated the agreement between a point-of-care with a reference laboratory analyzer for biochemistry variables in birds.
OBJECTIVES: The objective was to report reference intervals (RI) for plasma biochemistry variables in Strigiformes, and to assess agreement between the Abaxis Vetscan V2 and Roche Cobas c501.
METHODS: A prospective study was designed to assess plasma biochemistry RI for concentration of calcium, phosphorus, total protein, albumin, globulin, glucose, bilirubin, uric acid, bile acids, sodium, potassium, and chloride, and activities of AST, GGT, CK, amylase, lipase, LDH, and GLDH. In addition, the agreement between the Vetscan and the Cobas in owl species was assessed.
RESULTS: A total of 190 individuals were sampled belonging to 12 Strigiformes species including Barn Owls, Barred Owls, Great Horned Owls, Eurasian Eagle Owls, Spectacled Owls, Eastern Screech Owls, Long-Eared Owls, Short-Eared Owls, Great Gray Owls, Snowy Owls, Northern Saw-Whet Owls, and Northern Hawk-Owls. Order-, species-, and method-specific RI were determined on both analyzers. Although Vetscan data were not equivalent to the Cobas, 4 analytes (glucose, AST, CK, and total protein, with correction for bias) were within acceptable agreement, 3 analytes (uric acid, calcium, and phosphorus) were within close agreement, and the remaining analytes were in strong disagreement. Species-specific differences were observed notably for the concentration of glucose in Barn Owls and electrolytes in Northern Saw-Whet Owls.
CONCLUSIONS: Overall, this study suggests that the Vetscan has acceptable clinical performance in Strigiformes for some analytes and highlights discrepancies for several analytes.
© 2015 American Society for Veterinary Clinical Pathology.

Entities:  

Keywords:  Birds; clinical chemistry; method comparison; owls; point-of-care

Mesh:

Substances:

Year:  2015        PMID: 25613649     DOI: 10.1111/vcp.12230

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  5 in total

1.  Reference Intervals for Plasma Biochemical Variables by Point-of-Care Testing in Captive Black-tailed Prairie Dogs (Cynomys ludovicianus).

Authors:  David Eshar; Sara M Gardhouse; Diana Schwartz; Hugues Beaufrere
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-09-12       Impact factor: 1.232

2.  Reference Intervals for Selected Hematology and Clinical Chemistry Measurands in Temminck's Pangolin (Smutsia temminckii).

Authors:  Emma H Hooijberg; Karin Lourens; Leith C R Meyer
Journal:  Front Vet Sci       Date:  2021-07-08

3.  Hematologic and serum biochemical reference intervals of the Oriental white stork (Ciconia boyciana) and the application of an automatic hematologic analyzer.

Authors:  Jae-Ik Han; Hye-Jin Jang; Ki-Jeong Na
Journal:  J Vet Sci       Date:  2016-09-30       Impact factor: 1.672

4.  Biochemical reference intervals for homing pigeons in China.

Authors:  Mengjie Zheng; Qian Lv; Xinyu Fu; Fushan Shi
Journal:  Poult Sci       Date:  2020-05-06       Impact factor: 3.352

5.  Comparison of portable and conventional laboratory analyzers for biochemical tests in chickens.

Authors:  Fernando Ruiz-Jimenez; Erika Gruber; Maria Correa; Rocio Crespo
Journal:  Poult Sci       Date:  2020-12-01       Impact factor: 3.352

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.