Literature DB >> 25612182

Transient elastography for diagnosis of stages of hepatic fibrosis and cirrhosis in people with alcoholic liver disease.

Chavdar S Pavlov1, Giovanni Casazza, Dimitrinka Nikolova, Emmanuel Tsochatzis, Andrew K Burroughs, Vladimir T Ivashkin, Christian Gluud.   

Abstract

BACKGROUND: The presence and progression of hepatic (liver) fibrosis into cirrhosis is a prognostic variable having impact on survival in people with alcoholic liver disease. Liver biopsy, although an invasive method, is the recommended 'reference standard' for diagnosis and staging of hepatic fibrosis in people with liver diseases. Transient elastography is a non-invasive method for assessing and staging hepatic fibrosis.
OBJECTIVES: To determine the diagnostic accuracy of transient elastography for diagnosis and staging hepatic fibrosis in people with alcoholic liver disease when compared with liver biopsy. To identify the optimal cut-off values for differentiating the five stages of hepatic fibrosis. SEARCH
METHODS: The Cochrane Hepato-Biliary Group Controlled and Diagnostic Test Accuracy Studies Registers, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), and the Science Citation Index Expanded (last search August 2014). SELECTION CRITERIA: Diagnostic cohort and diagnostic case-control study designs that assessed hepatic fibrosis in participants with alcoholic liver disease with transient elastography and liver biopsy, irrespective of language or publication status. The study participants could be of any sex and ethnic origin, above 16 years old, hospitalised or managed as outpatients. We excluded participants with viral hepatitis, autoimmunity, metabolic diseases, and toxins. DATA COLLECTION AND ANALYSIS: We followed the guidelines in the draft Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. MAIN
RESULTS: Five retrospective and nine prospective cohort studies with 834 participants provided data for the review analyses. Authors of seven of those studies sent us individual participant data. The risk of bias in the included studies was high in all but three studies. We could identify no serious concerns regarding the applicability of the studies in answering the main study question of our review, namely to use transient elastography to diagnose hepatic fibrosis. We could not identify the optimal cut-off values for the fibrosis stages. The definition of the diagnosis of alcoholic liver disease was not provided in one study and was not clearly defined in two studies, but it was clear in the remaining 11 studies. The study authors used different liver stiffness cut-off values of transient elastography for the hepatic fibrosis stages.There was only one study (103 participants) with data on hepatic fibrosis stage F1 or worse, with a cut-off of 5.9 kPa, and reporting sensitivity of 0.83 (95% confidence interval (CI) 0.74 to 0.90) and specificity of 0.88 (95% CI 0.47 to 1.00). The summary sensitivity and specificity of transient elastography for F2 or worse (seven studies with 338 participants and with cut-offs around 7.5 kPa (range 7.00 to 7.8 kPa)) were 0.94 and 0.89 with LR+ 8.2 and LR- 0.07, which suggests that transient elastography could be useful to rule out the presence of significant hepatic fibrosis, thus avoiding liver biopsy.Due to the wide range of cut-off values (from 8.0 to 17.0 kPa) found in the 10 studies with 760 participants with hepatic fibrosis F3 or worse, we fitted a hierarchical summary receiver operating characteristic (HSROC) model and estimated a summary ROC (SROC) curve. The sensitivity of the 10 studies varied from 72% to 100% and the specificity from 59% to 89%. We performed an additional analysis by including the studies with a cut-off value of around and equal to 9.5 kPa (range 8.0 to 11.0 kPa). The summary sensitivity and specificity of transient elastography (eight studies with 564 participants) were 0.92 and 0.70 with LR+ 3.1 and LR- 0.11, which suggests that transient elastography could also be useful to rule out the presence of severe hepatic fibrosis (F3 or worse), avoiding liver biopsy. We carried out a sensitivity analysis by considering only the studies with a cut-off value equal to 9.5 kPa and the result did not differ.We performed an HSROC analysis and reported an SROC curve for hepatic fibrosis stage F4 (cirrhosis). The HSROC analysis suggested that when the cut-off value changes, there is a wide variation in specificity and a more limited variation in sensitivity. We performed an additional analysis with the studies with the most commonly used cut-off value of 12.5 kPa. The summary sensitivity and specificity of transient elastography (seven studies with 330 participants) were 0.95 and 0.71 with LR+ 3.3 and LR- 0.07, which again suggests that transient elastography could be useful to rule out the presence of cirrhosis, avoiding liver biopsy. AUTHORS'
CONCLUSIONS: We identified a small number of studies with a few participants and were unable to include several studies, which raises the risk of outcome reporting bias. With these caveats in mind, transient elastography may be used as a diagnostic method to rule out liver cirrhosis (F4) in people with alcoholic liver disease when the pre-test probability is about 51% (range 15% to 79%). Transient elastography may also help in ruling out severe fibrosis (F3 or worse). Liver biopsy investigation remains an option if the certainty to rule in or rule out the stage of hepatic fibrosis or cirrhosis remains insufficient after a clinical follow-up or any other non-invasive test considered useful by the clinician.The proposed cut-off values for the different stages of hepatic fibrosis may be used in clinical practice, but caution is needed, as those values reported in this review are only the most common cut-off values used by the study authors. The best cut-off values for hepatic fibrosis in people with alcoholic liver disease could not be established yet.In order to diagnose correctly the stage of hepatic fibrosis in people with alcoholic liver disease using transient elastography assessment, the studies should consider a single aetiology. Hepatic fibrosis should be diagnosed with both transient elastography and liver biopsy and in this sequence, and transient elastography cut-off values should be pre-specified and validated. The time interval between the two investigations should not exceed three months, which is the interval mainly valid for people without cirrhosis, and assessment of results should be properly blinded. Only studies with low risk of bias, fulfilling the Standards for Reporting of Diagnostic Accuracy may answer the review question.

Entities:  

Mesh:

Year:  2015        PMID: 25612182      PMCID: PMC7081746          DOI: 10.1002/14651858.CD010542.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  92 in total

1.  Guidelines on the use of liver biopsy in clinical practice. British Society of Gastroenterology.

Authors:  A Grant; J Neuberger
Journal:  Gut       Date:  1999-10       Impact factor: 23.059

2.  The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed.

Authors:  Jonathan J Deeks; Petra Macaskill; Les Irwig
Journal:  J Clin Epidemiol       Date:  2005-09       Impact factor: 6.437

Review 3.  Alcoholic liver disease.

Authors:  Robert S O'Shea; Srinivasan Dasarathy; Arthur J McCullough
Journal:  Hepatology       Date:  2010-01       Impact factor: 17.425

4.  Prediction of risk of liver disease by alcohol intake, sex, and age: a prospective population study.

Authors:  U Becker; A Deis; T I Sørensen; M Grønbaek; K Borch-Johnsen; C F Müller; P Schnohr; G Jensen
Journal:  Hepatology       Date:  1996-05       Impact factor: 17.425

5.  Variant adiponutrin (PNPLA3) represents a common fibrosis risk gene: non-invasive elastography-based study in chronic liver disease.

Authors:  Marcin Krawczyk; Frank Grünhage; Vincent Zimmer; Frank Lammert
Journal:  J Hepatol       Date:  2010-12-17       Impact factor: 25.083

6.  YKL-40 and transient elastography, a powerful team to assess hepatic fibrosis.

Authors:  Timo Rath; Martin Roderfeld; Can Güler; Christian Wenzel; Jürgen Graf; Frigga Beitinger; Elke Roeb; Reinhart Zachoval
Journal:  Scand J Gastroenterol       Date:  2011-09-12       Impact factor: 2.423

7.  Transient elastography for predicting clinical outcomes in patients with chronic liver disease.

Authors:  D A Klibansky; S H Mehta; M Curry; I Nasser; T Challies; N H Afdhal
Journal:  J Viral Hepat       Date:  2011-07-01       Impact factor: 3.728

Review 8.  Hepatology may have problems with putative surrogate outcome measures.

Authors:  Christian Gluud; Jesper Brok; Yan Gong; Ronald L Koretz
Journal:  J Hepatol       Date:  2007-01-26       Impact factor: 25.083

9.  Assessment of hepatic fibrosis with magnetic resonance elastography.

Authors:  Meng Yin; Jayant A Talwalkar; Kevin J Glaser; Armando Manduca; Roger C Grimm; Phillip J Rossman; Jeff L Fidler; Richard L Ehman
Journal:  Clin Gastroenterol Hepatol       Date:  2007-10       Impact factor: 11.382

10.  Formulation and application of a numerical scoring system for assessing histological activity in asymptomatic chronic active hepatitis.

Authors:  R G Knodell; K G Ishak; W C Black; T S Chen; R Craig; N Kaplowitz; T W Kiernan; J Wollman
Journal:  Hepatology       Date:  1981 Sep-Oct       Impact factor: 17.425

View more
  30 in total

Review 1.  Noninvasive assessment of alcoholic liver disease using unidimensional transient elastography (Fibroscan(®)).

Authors:  Monica Lupsor-Platon; Radu Badea
Journal:  World J Gastroenterol       Date:  2015-11-14       Impact factor: 5.742

2.  Noninvasive Measures of Liver Fibrosis and Severity of Liver Disease.

Authors:  Catherine Lucero; Robert S Brown
Journal:  Gastroenterol Hepatol (N Y)       Date:  2016-01

3.  Volumetric multicomponent T relaxation mapping of the human liver under free breathing at 3T.

Authors:  Azadeh Sharafi; Rahman Baboli; Marcelo Zibetti; Krishna Shanbhogue; Sonja Olsen; Tobias Block; Hersh Chandarana; Ravinder Regatte
Journal:  Magn Reson Med       Date:  2019-11-14       Impact factor: 4.668

Review 4.  Clinical applications, limitations and future role of transient elastography in the management of liver disease.

Authors:  Pik Eu Chang; George Boon-Bee Goh; Jing Hieng Ngu; Hiang Keat Tan; Chee Kiat Tan
Journal:  World J Gastrointest Pharmacol Ther       Date:  2016-02-06

Review 5.  Non-invasive assessment of liver fibrosis in patients with alcoholic liver disease.

Authors:  Rosa Lombardi; Elena Buzzetti; Davide Roccarina; Emmanuel A Tsochatzis
Journal:  World J Gastroenterol       Date:  2015-10-21       Impact factor: 5.742

6.  Liver reserve function assessment by acoustic radiation force impulse imaging.

Authors:  Xiao-Lan Sun; Li-Wei Liang; Hui Cao; Qiong Men; Ke-Zhu Hou; Zhen Chen; Ya-E Zhao
Journal:  World J Gastroenterol       Date:  2015-08-28       Impact factor: 5.742

7.  Prednisolone plus S-adenosil-L-methionine in severe alcoholic hepatitis.

Authors:  Petr Tkachenko; Marina Maevskaya; Alexander Pavlov; Inna Komkova; Chavdar Pavlov; Vladimir Ivashkin
Journal:  Hepatol Int       Date:  2016-06-23       Impact factor: 6.047

8.  Usefulness of virtual touch tissue quantification for predicting the presence of esophageal varices in patients with liver cirrhosis.

Authors:  Teppei Matsui; Hidenari Nagai; Gou Watanabe; Naoyuki Yoshimine; Makoto Amanuma; Kojiro Kobayashi; Yuu Ogino; Takanori Mukozu; Yasushi Matsukiyo; Yasuko Daido; Noritaka Wakui; Shigeru Nakano; Mie Shinohara; Koichi Momiyama; Takehide Kudo; Kenichi Maruyama; Yoshinori Igarashi
Journal:  JGH Open       Date:  2021-05-13

Review 9.  Alcohol-Related Liver Disease: Basic Mechanisms and Clinical Perspectives.

Authors:  Szu-Yi Liu; I-Ting Tsai; Yin-Chou Hsu
Journal:  Int J Mol Sci       Date:  2021-05-13       Impact factor: 5.923

10.  Using vibration controlled transient elastography and FIB-4 to assess liver cirrhosis in a hepatitis C virus infected population.

Authors:  Nabil Saleem; Lesley S Miller; Alia S Dadabhai; Emily J Cartwright
Journal:  Medicine (Baltimore)       Date:  2021-06-11       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.