Literature DB >> 25608834

Histomorphological and torque removal comparison of 6 mm orthodontic miniscrews with and without surface treatment in New Zealand rabbits.

Arthessarat Sirisa-Ard1, Sabrina Natalie Woodroffe Michael1, Kamal Ahmed1, Colin R Dunstan2, Simon G Pearce3, Ayse Aysin Bilgin4, Oyku Dalci5, M Ali Darendeliler1.   

Abstract

AIM: The purpose of this study was to assess the difference of removal torque values (RTV) and the bone-to-implant contact (BIC) between the sand-blasted, large grit, and acid-etched (SLA) surface-treated and the machined surface (MA) miniscrews.
MATERIAL AND METHODS: Miniscrews used in this study were 6mm long with a diameter of 1.5mm. A total of 23 SLA miniscrews and 24 MA miniscrews were placed into the distal femoral condyle of 24 New Zealand rabbits. Removal torque test and the BIC was histologically evaluated at 0 and 8 weeks.
RESULTS: There was no statistical difference between the RTV in the MA group versus the SLA group at both 0 and 8 weeks. Comparing 0-8 weeks, there was no significant difference in RTV of the SLA group (P = 0.48), however the change in the MA group was statistically significant (P = 0.006). Histological observation showed a significant decrease in BIC comparing 0 and 8 weeks for the MA group. The BIC ratio at 8 weeks was statistically significantly higher in the SLA group compared to the MA group.
CONCLUSION: SLA surface preparation does not increase the RTV of miniscrews. Further investigations under loading and a large sample size are required.
© The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25608834     DOI: 10.1093/ejo/cju077

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  3 in total

1.  Evaluation of osseous integration of titanium orthopedic screws with novel SLA treatment in porcine model.

Authors:  Tzu-Hsiang Lin; Hsin-Tai Hu; Hsueh-Chun Wang; Meng-Chian Wu; Shu-Wei Wu; Ming-Long Yeh
Journal:  PLoS One       Date:  2017-11-17       Impact factor: 3.240

2.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

3.  Degradation and Biocompatibility of AZ31 Magnesium Alloy Implants In Vitro and In Vivo: A Micro-Computed Tomography Study in Rats.

Authors:  Naohiko Kawamura; Yuya Nakao; Rina Ishikawa; Dai Tsuchida; Masahiro Iijima
Journal:  Materials (Basel)       Date:  2020-01-19       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.