Literature DB >> 25608598

Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.

Denis Monneret1, Fouzi Mestari, Gregory Atlan, Camille Corlouer, Zo Ramani, Jeremy Jaffre, Sylvie Dever, Veronique Fressart, Rana Alkouri, Foudil Lamari, Catherine Devilliers, Françoise Imbert-Bismut, Dominique Bonnefont-Rousselot.   

Abstract

OBJECTIVES: To determine the hemolysis interference on biochemical tests and immunoassays performed on Roche Diagnostics analyzers, according to different maximum allowable limits. DESIGN AND METHODS: Heparinized plasma and serum pools, free of interferences, were overloaded by increasing amounts of a hemoglobin-titrated hemolysate. This interference was evaluated for 45 analytes using Modular(®) and Cobas(®) analyzers. For each parameter, the hemolysis index (HI) corresponding to the traditional ± 10% change of concentrations from baseline (± 10%Δ) was determined, as well as those corresponding to the analytical change limit (ACL), and to the reference change value (RCV). Then, the relative frequencies distribution (% RFD) of hemolyzed tests performed in a hospital laboratory over a 25-day period were established for each HI as allowable limit.
RESULTS: Considering the ± 10%Δ, the analyte concentrations enhanced by hemolysis were: Lactate dehydrogenase (LDH), aspartate aminotransferase (AST), folate, potassium, creatine kinase, phosphorus, iron, alanine aminotransferase, lipase, magnesium and triglycerides, decreasingly. The analyte concentrations decreased by hemolysis were: Haptoglobin, high-sensitive troponin T and alkaline phosphatase. Over the 25-day period, the % RFD of tests impacted more than 10%Δ by hemolysis were < 7% for LDH; < 5% for AST, folates and iron; and < 1% for the other analytes. Considering the ACL, HI were lower, giving % RFD substantially increased for many analytes, whereas only four analytes remain sensitive to hemolysis when considering RCV.
CONCLUSION: This study proposes new HI based on different allowable limits, and can therefore serve as a starting point for future harmonization of hemolysis interference evaluation needed in routine laboratory practice.

Entities:  

Keywords:  Hemolysis indexes; hemoglobin; hemolysis interference; maximum allowable limits

Mesh:

Substances:

Year:  2015        PMID: 25608598     DOI: 10.3109/00365513.2014.993691

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  11 in total

1.  Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses.

Authors:  Alain Nicolay; Anne-Marie Lorec; Guy Gomez; Henri Portugal
Journal:  J Clin Lab Anal       Date:  2017-04-11       Impact factor: 2.352

2.  Interferograms plotted with reference change value (RCV) may facilitate the management of hemolyzed samples.

Authors:  Kamil Taha Uçar; Abdulkadir Çat; Alper Gümüş; Nilhan Nurlu
Journal:  J Med Biochem       Date:  2022-02-02       Impact factor: 3.402

3.  Pathologic Blood Samples Tolerate Exposure to Vibration and High Turbulence in Simulated Drone Flights, but Plasma Samples Should be Centrifuged After Flight.

Authors:  Karl Arne Johannessen; Nina Kristin Steen Wear; Karin Toska; Morten Hansbo; Jens Petter Berg; Erik Fosse
Journal:  IEEE J Transl Eng Health Med       Date:  2021-01-20       Impact factor: 3.316

4.  Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer.

Authors:  Zhenhua Du; JiQin Liu; Hua Zhang; BuHe Bao; RuiQi Zhao; Ying Jin
Journal:  J Clin Lab Anal       Date:  2019-02-19       Impact factor: 2.352

5.  Cardiac Troponin T in Healthy Full-Term Infants.

Authors:  Jonna Karlén; Mathias Karlsson; Håkan Eliasson; Anna-Karin Edstedt Bonamy; Cecilia Pegelow Halvorsen
Journal:  Pediatr Cardiol       Date:  2019-09-05       Impact factor: 1.655

6.  A Reference chart for clinical biochemical tests of hemolyzed serum samples.

Authors:  Jun Ni; Wenbo Zhu; Yanyang Wang; Xuefei Wei; Jingjing Li; Lu Peng; Kui Zhang; Bing Bai
Journal:  J Clin Lab Anal       Date:  2020-09-02       Impact factor: 2.352

7.  Interference of hemolysis on the postmortem biochemical analysis of IgE by ECLIA.

Authors:  Tianqi Wang; Zeyu Li; Yuqing Jia; Baoli Zhu; Zhipeng Cao
Journal:  Int J Legal Med       Date:  2021-03-30       Impact factor: 2.686

8.  Frequency of icteric interference in clinical chemistry laboratory tests and causes of severe icterus.

Authors:  Sandhya Mainali; Anna E Merrill; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2021-10-23

9.  Frequency and causes of lipemia interference of clinical chemistry laboratory tests.

Authors:  Sandhya Mainali; Scott R Davis; Matthew D Krasowski
Journal:  Pract Lab Med       Date:  2017-02-03

10.  The incidence rate and influence factors of hemolysis, lipemia, icterus in fasting serum biochemistry specimens.

Authors:  Gang Tian; Yu Wu; Xinrui Jin; Zhangrui Zeng; Xiujuan Gu; Tao Li; Xiu Chen; Guangrong Li; Jinbo Liu
Journal:  PLoS One       Date:  2022-01-19       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.