Literature DB >> 25608027

Eddy covariance flux measurements of gaseous elemental mercury using cavity ring-down spectroscopy.

Ashley M Pierce1, Christopher W Moore, Georg Wohlfahrt, Lukas Hörtnagl, Natascha Kljun, Daniel Obrist.   

Abstract

A newly developed pulsed cavity ring-down spectroscopy (CRDS) system for measuring atmospheric gaseous elemental mercury (GEM) concentrations at high temporal resolution (25 Hz) was used to successfully conduct the first eddy covariance (EC) flux measurements of GEM. GEM is the main gaseous atmospheric form, and quantification of bidirectional exchange between the Earth's surface and the atmosphere is important because gas exchange is important on a global scale. For example, surface GEM emissions from natural sources, legacy emissions, and re-emission of previously deposited anthropogenic pollution may exceed direct primary anthropogenic emissions. Using the EC technique for flux measurements requires subsecond measurements, which so far has not been feasible because of the slow time response of available instrumentation. The CRDS system measured GEM fluxes, which were compared to fluxes measured with the modified Bowen ratio (MBR) and a dynamic flux chamber (DFC). Measurements took place near Reno, NV, in September and October 2012 encompassing natural, low-mercury (Hg) background soils and Hg-enriched soils. During nine days of measurements with deployment of Hg-enriched soil in boxes within 60 m upwind of the EC tower, the covariance of GEM concentration and vertical wind speed was measured, showing that EC fluxes over an Hg-enriched area were detectable. During three separate days of flux measurements over background soils (without Hg-enriched soils), no covariance was detected, indicating fluxes below the detection limit. When fluxes were measurable, they strongly correlated with wind direction; the highest fluxes occurred when winds originated from the Hg-enriched area. Comparisons among the three methods showed good agreement in direction (e.g., emission or deposition) and magnitude, especially when measured fluxes originated within the Hg-enriched soil area. EC fluxes averaged 849 ng m(-2) h(-1), compared to DFC fluxes of 1105 ng m(-2) h(-1) and MBR fluxes of 1309 ng m(-2) h(-1). This study demonstrated that a CRDS system can be used to measure GEM fluxes over Hg-enriched areas, with a conservative detection limit estimate of 32 ng m(-2) h(-1).

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25608027     DOI: 10.1021/es505080z

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  2 in total

1.  Mercury biogeochemical cycling: A synthesis of recent scientific advances.

Authors:  Mae Sexauer Gustin; Michael S Bank; Kevin Bishop; Katlin Bowman; Brian Branfireun; John Chételat; Chris S Eckley; Chad R Hammerschmidt; Carl Lamborg; Seth Lyman; Antonio Martínez-Cortizas; Jonas Sommar; Martin Tsz-Ki Tsui; Tong Zhang
Journal:  Sci Total Environ       Date:  2020-05-23       Impact factor: 7.963

2.  Eddy covariance carbonyl sulphide flux measurements with a quantum cascade laser absorption spectrometer.

Authors:  Katharina Gerdel; Felix Maximilian Spielmann; Albin Hammerle; Georg Wohlfahrt
Journal:  Atmos Meas Tech       Date:  2017-09-26       Impact factor: 4.176

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.