Tsachi Tsadok Perets1,2, Einav Shporn1, Doron Boltin3,2, Ram Dickman3,2, Yaron Niv3,2. 1. Gastroenterology Laboratory, Rabin Medical Center - Beilinson Hospital, Petah Tikva, Israel. 2. Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel. 3. Department of Gastroenterology, Rabin Medical Center - Beilinson Hospital, Petah Tikva, Israel.
Abstract
BACKGROUND: The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. METHODS: A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. RESULTS: Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. CONCLUSION: Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats.
BACKGROUND: The accuracy and repeatability of breath test in the diagnosis of Helicobacter pylori infection have not been adequately investigated. Although it has been shown that storage for long periods does not affect the analysis results, no data are available on the effect of repetitive testing. In this study, our aim was to evaluate the repeatability of the analyses of breath samples at room temperature. METHODS: A total of 202 positive breath samples were collected in duplicates, before and after administration of 75 mg (13) C- urea dissolved in 100 ml of orange juice. Breath test results were expressed as delta (13) CO2 . The cut-off value was 3.5 parts per thousand. Each sample was analyzed in a mass spectrometer 7, 14, 21, and 28 days after collection. The accuracy calculation was based on the comparison of the delta (13) CO2 obtained in the three consecutive weeks following the first test run to the delta (13) CO2 obtained in the first test run. RESULTS: Two hundred (99%), 197 (97.52%), and 196 (97%) of the 202 samples tested positive in the second, third, and fourth test runs, respectively. The accuracy of the delta (13) CO2 was 98.6%, 99.2%, and 96.7% in the three consecutive runs, respectively. CONCLUSION: Short-term storage of 1 month does not affect sample stability or the results of (13) C-urea breath tests in up to three consecutive repeats.
Authors: T A Di Rienzo; G D'Angelo; V Ojetti; M C Campanale; A Tortora; V Cesario; G Zuccalà; F Franceschi Journal: Eur Rev Med Pharmacol Sci Date: 2013 Impact factor: 3.507
Authors: Jeongmin Choi; Chung Hyeon Kim; Donghee Kim; Su Jin Chung; Ji Hyun Song; Jung Mook Kang; Jong In Yang; Min Jung Park; Young Sun Kim; Jeong Yoon Yim; Seon Hee Lim; Joo Sung Kim; Hyun Chae Jung; In Sung Song Journal: J Gastroenterol Hepatol Date: 2011-06 Impact factor: 4.029
Authors: David J Beale; Oliver A H Jones; Avinash V Karpe; Saravanan Dayalan; Ding Yuan Oh; Konstantinos A Kouremenos; Warish Ahmed; Enzo A Palombo Journal: Int J Mol Sci Date: 2016-12-23 Impact factor: 5.923