Literature DB >> 25599781

Myocardial integrated ultrasonic backscatter for early detection of cardiac involvement in patients with Wilson disease.

Nurcan Arat1, Sabite Kaçar, Zehra Gölbaşı, Meral Akdoğan, Sedef Kuran.   

Abstract

BACKGROUND/AIMS: Videodensitometry is a feasible noninvasive ultrasound tissue characterization method allowing early detection of myocardial changes. This study aimed to investigate ultrasonic backscatter properties of the myocardium in Wilson disease patients.
MATERIALS AND METHODS: We compared cardiologically asymptomatic Wilson disease patients (W group) (n=18) with age-matched (26.7±9.6 years) healthy controls (C group) (n=15). Diagnosis of Wilson disease was made on the basis of clinical manifestations, family history, and laboratory findings and confirmed by liver biopsy. Transthoracic echocardiographic quantitative texture analysis was performed on data from the septum and left ventricular posterior wall, and mean gray level (MGL) histograms at end-diastole (d) and end-systole (s) were obtained after background correction (c). Cyclic variation index (CVI) was calculated using the formula [(cMGLd - cMGLs) / cMGLd] ×100.
RESULTS: There were no significant differences in sex, age, body mass index, heart rate or blood pressure, and conventional echocardiographic parameters between the 2 groups. The cMGLs value of the posterior wall was higher in the W group than in the C group (30.9±2.6 vs. 22.2±2.7, p=0.033). The W group had a significantly lower CVI of the septum than did the C group (-22±4.4% vs. 43.4 ±12.9%, p<0.001), and there was no significant difference in the CVI of the posterior wall (-67.0±15.9% vs. 41.7±18.6%, p=0.32).
CONCLUSION: Abnormalities in two-dimensional echocardiographic grey-level distributions were present in Wilson disease patients. These videodensitometric myocardial alterations were significantly lower in Wilson disease patients than in the controls, and this probably represents an early stage of cardiac involvement.

Entities:  

Mesh:

Year:  2014        PMID: 25599781     DOI: 10.5152/tjg.2014.5949

Source DB:  PubMed          Journal:  Turk J Gastroenterol        ISSN: 1300-4948            Impact factor:   1.852


  3 in total

1.  Autonomic Dysfunction in Wilson's Disease: A Comprehensive Evaluation during a 3-Year Follow Up.

Authors:  Kai Li; Charlotte Lindauer; Rocco Haase; Heinz Rüdiger; Heinz Reichmann; Ulrike Reuner; Tjalf Ziemssen
Journal:  Front Physiol       Date:  2017-10-10       Impact factor: 4.566

2.  Cardiac assessment in Wilson's disease patients based on electrocardiography and echocardiography examination.

Authors:  Małgorzata Buksińska-Lisik; Tomasz Litwin; Tomasz Pasierski; Anna Członkowska
Journal:  Arch Med Sci       Date:  2017-09-07       Impact factor: 3.318

3.  Cardiac arrhythmia in Wilson's disease: An oversighted and overlooked entity!

Authors:  Bhupender Kumar Bajaj; Ankur Wadhwa; Richa Singh; Saurabh Gupta
Journal:  J Neurosci Rural Pract       Date:  2016 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.