| Literature DB >> 25597804 |
Seta Noventa1, Jvan Barbaro2, Malgorzata Formalewicz3, Claudia Gion3, Federico Rampazzo3, Rossella Boscolo Brusà3, Massimo Gabellini4, Daniela Berto3.
Abstract
This work validated an automated, fast, and low solvent- consuming methodology suited for routine analysis of tributyltin (TBT) and degradation products (dibutyltin, DBT; monobutyltin, MBT) in biota samples. The method was based on the headspace solid-phase microextraction methodology (HS-SPME), coupled with gas chromatographic separation and tandem mass-spectrometry (GC-MS/MS). The effectiveness of the matrix-matched signal ratio external calibration was tested for quantification purposes. The exclusion of matrix influences in the calibration curves proved the suitability of this versatile quantification method. The method detection limits obtained were of 3 ng Sn g(-1) dw for all the analytes. The analysis of references materials showed satisfying accuracy under optimum calibration conditions (% recovery between 87-111%; |Z-scores|<2). The repeatability RSD% and intra-laboratory reproducibility RSD% were lower than 9.6% and 12.6%, respectively. The work proved the remarkable analytical performances of the method and its high potential for routine application in monitoring organotin compounds (OTC).Entities:
Keywords: Biota; Calibration; Organotin; Routine; Solid phase microextraction; Tributyltin
Mesh:
Substances:
Year: 2014 PMID: 25597804 DOI: 10.1016/j.aca.2014.11.028
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558