Literature DB >> 25596984

Femoral head diameter considerations for primary total hip arthroplasty.

J Girard1.   

Abstract

The configuration of total hip arthroplasty (THA) implants has constantly evolved since they were first introduced. One of the key components of THA design is the diameter of the prosthetic femoral head. It has been well established that the risk of dislocation is lower as the head diameter increases. But head diameter impacts other variables beyond joint stability: wear, cam-type impingement, range of motion, restoration of biomechanics, proprioception and groin pain. The introduction of highly cross-linked polyethylene and hard-on-hard bearings has allowed surgeons to implant large-diameter heads that almost completely eliminate the risk of dislocation. But as a result, cup liners have become thinner. With femoral head diameters up to 36 mm, the improvement in joint range of motion, delay in cam-type impingement and reduction in dislocation risk have been clearly demonstrated. Conversely, large-diameter heads do not provide any additional improvements. If an "ecologically sound" approach to hip replacement is embraced (e.g. keeping the native femoral head diameter), hip resurfacing with a metal-on-metal bearing must be carried out. The reliability of large-diameter femoral heads in the longer term is questionable. Large-diameter ceramic-on-ceramic bearings may be plagued by the same problems as metal-on-metal bearings: groin pain, squeaking, increased stiffness, irregular lubrication, acetabular loosening and notable friction at the Morse taper. These possibilities require us to be extra careful when using femoral heads with a diameter greater than 36 mm.
Copyright © 2014 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Aseptic loosening; Dislocation; Hip resurfacing; Large-diameter femoral head

Mesh:

Year:  2015        PMID: 25596984     DOI: 10.1016/j.otsr.2014.07.026

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  14 in total

1.  CORR Insights®: Short-term Risk of Revision THA in the Medicare Population Has Not Improved With Time.

Authors:  Julien Girard
Journal:  Clin Orthop Relat Res       Date:  2016-01       Impact factor: 4.176

2.  Adventure sports and sexual freedom hip replacement: the tripolar hip.

Authors:  James W Pritchett
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-28

3.  No Increase in Survival for 36-mm versus 32-mm Femoral Heads in Metal-on-polyethylene THA: A Registry Study.

Authors:  Georgios Tsikandylakis; Johan Kärrholm; Nils P Hailer; Antti Eskelinen; Keijo T Mäkelä; Geir Hallan; Ove Nord Furnes; Alma B Pedersen; Søren Overgaard; Maziar Mohaddes
Journal:  Clin Orthop Relat Res       Date:  2018-12       Impact factor: 4.176

4.  Dual Mobility Total Hip Arthroplasty Is Not Associated with a Greater Incidence of Groin Pain in Comparison with Conventional Total Hip Arthroplasty and Hip Resurfacing:A Retrospective Comparative Study.

Authors:  Alexandra I Stavrakis; Amir Khoshbin; Amethia Joseph; Lily Y Lee; Mathias P Bostrom; Geoffrey H Westrich; Alexander S McLawhorn
Journal:  HSS J       Date:  2020-08-04

Review 5.  Large Diameter Head in Primary Total Hip Arthroplasty: A Systematic Review.

Authors:  G Neupane; R Madhusudhan; A Shrestha; R Vaishya
Journal:  Indian J Orthop       Date:  2020-05-29       Impact factor: 1.251

6.  Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: What is the evidence?

Authors:  Didier Hannouche; Matthieu Zingg; Hermes Miozzari; Remy Nizard; Anne Lübbeke
Journal:  EFORT Open Rev       Date:  2018-01-10

7.  Total hip arthroplasty: Survival and modes of failure.

Authors:  Theofilos Karachalios; George Komnos; Antonios Koutalos
Journal:  EFORT Open Rev       Date:  2018-05-21

8.  Head size in primary total hip arthroplasty.

Authors:  Georgios Tsikandylakis; Maziar Mohaddes; Peter Cnudde; Antti Eskelinen; Johan Kärrholm; Ola Rolfson
Journal:  EFORT Open Rev       Date:  2018-05-21

9.  Static structural analysis of different stem designs used in total hip arthroplasty using finite element method.

Authors:  Chethan K N; Mohammad Zuber; Shyamasunder Bhat N; Satish Shenoy B; Chandrakant R Kini
Journal:  Heliyon       Date:  2019-06-12

10.  Hip Arthroplasty Instability After Implantation of a Spinal Cord Stimulator.

Authors:  Cambize Shahrdar; Kevin P Smidt
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.