Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography.

Eun Sun Lee1, Se Hyung Kim2, Jong Pil Im3, Sang Gyun Kim3, Cheong-Il Shin1, Joon Koo Han1, Byung Ihn Choi1.   

Abstract

PURPOSE: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC).
MATERIALS AND METHODS: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms.
RESULTS: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps<6 mm, 52 6-9.9 mm, and 38≥10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P<0.017). Per-polyp sensitivity for polyps≥10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P>0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P=0.011).
CONCLUSION: Although the performance of stand-alone CAD for ULD CTC can be improved, IR algorithms, particularly MBIR, were shown to significantly increase the per-polyp sensitivity of CAD compared to FBP according to this study. Therefore, as ULD CTC only requires 1.02mSv, specific optimization of CAD for ULD CTC and IR algorithms is strongly warranted to make ULD CTC with CAD clinically viable.
Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Colonic polyps; Computed tomographic colonography; Computer-assisted diagnosis; Radiation protection

Mesh:

Year:  2014        PMID: 25596916     DOI: 10.1016/j.ejrad.2014.11.031

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  1 in total

1.  Coronary computed tomography angiography using model-based iterative reconstruction algorithms in the detection of significant coronary stenosis: how the plaque type influences the diagnostic performance.

Authors:  Antonio Vizzuso; Riccardo Righi; Aldo Carnevale; Michela Zerbini; Giorgio Benea; Melchiore Giganti
Journal:  Pol J Radiol       Date:  2019-12-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.