Literature DB >> 25594704

TIPS geometry influences patency.

J Klasen-Sansone1, J Bode2, R S Lanzman1, R Kubitz2, S Immig2, P Heusch1, G Antoch1, D Häussinger2, D Blondin1.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate potential causes of Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction.
MATERIAL AND METHODS: We retrospectively evaluated 26 patients who required TIPS revision (group I) and 24 patients who did not require any further intervention (group II) within the first two years following TIPS implantation. The distance of the distal end of the stent to the hepatocaval junction was measured. Furthermore, the angle between the stent and the portal vein (inflow) and the angle between the stent and the hepatic vein (outflow) were measured. Furthermore, the following data were evaluated: pre- and postinterventional portal pressure gradients, maximal postinterventional flow and blood values [C-reactive protein (CRP), bilirubin, glutamic-oxaloacetic transaminase (GOT), glutamic-pyruvic transaminase (GPT)].
RESULTS: Compared with control subjects, patients who required TIPS revision showed a significantly longer distance from the distal end of the stent to the hepatocaval junction (I: 17.3 ± 10 mm, II: 6.7 ± 5.7 mm, p < 0.001). There was a statistically significant correlation between the above named distance and the time to revision (Pearson's correlation coefficient, r = 0.5, p = 0.01). In addition, patients with TIPS revision had a significantly larger angle of portalvenous inflow (alpha angle) than the control group (I: 100.5 ± 31.5°, II: 64.5 ± 31.6°, p < 0.001).
CONCLUSION: Our results show that the distance from the end of the stent to the hepatocaval junction and the angle of portalvenous inflow are technical factors that may influence the shunt's patency rate. Of these two, the distance to the hepatocaval junction can be influenced easily by the interventionalist. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2015        PMID: 25594704     DOI: 10.1055/s-0034-1385430

Source DB:  PubMed          Journal:  Z Gastroenterol        ISSN: 0044-2771            Impact factor:   2.000


  6 in total

1.  Predicting death or recurrence of portal hypertension symptoms after TIPS procedures.

Authors:  Shawn H Sun; Thomas Eche; Chloé Dorczynski; Philippe Otal; Paul Revel-Mouroz; Charline Zadro; Ephraim Partouche; Nadim Fares; Charlotte Maulat; Christophe Bureau; Lawrence H Schwartz; Hervé Rousseau; Laurent Dercle; Fatima-Zohra Mokrane
Journal:  Eur Radiol       Date:  2022-01-11       Impact factor: 5.315

2.  Retrospective evaluation of early thrombosis in transjugular intrahepatic portosystemic polytetrafluoroethylene-coated shunts under 2-day postinterventional heparinization.

Authors:  Holger Goessmann; Verna Schuffenhauer; Arne Kandulski; Kilian Weigand; Ernst-Michael Jung; Wibke Uller; Gregor Scharf; Cristian Stroszczynski; Niklas Verloh
Journal:  Sci Rep       Date:  2022-06-22       Impact factor: 4.996

3.  Impact of PTFE-covered stent position and extension on TIPS patency.

Authors:  Joshua K Cho; Juan Serna; Timothy W I Clark; Mandeep Dagli; Jeffrey I Mondschein; Richard D Shlansky-Goldberg; Scott O Trerotola; Michael C Soulen; S William Stavropoulos; Gregory J Nadolski
Journal:  Abdom Radiol (NY)       Date:  2020-11

4.  A new choice of stent for transjugular intrahepatic portosystemic shunt creation: Viabahn ePTFE covered stent/bare metal stent combination.

Authors:  Jiacheng Liu; Jie Meng; Chen Zhou; Qin Shi; Chongtu Yang; Jinqiang Ma; Manman Chen; Bin Xiong
Journal:  J Interv Med       Date:  2020-10-13

5.  Cranial stent position is independently associated with the development of TIPS dysfunction.

Authors:  Carsten Meyer; Alba Maria Paar Pérez; Johannes Chang; Alois Martin Sprinkart; Nina Böhling; Andreas Minh Luu; Daniel Kütting; Christian Jansen; Julian Luetkens; Leon Marcel Bischoff; Ulrike Attenberger; Christian P Strassburg; Jonel Trebicka; Karsten Wolter; Michael Praktiknjo
Journal:  Sci Rep       Date:  2022-03-03       Impact factor: 4.379

6.  Anatomic Variations of the Right Portal Vein: Prevalence, Imaging Features, and Implications for Successful Transjugular Intrahepatic Portosystemic Shunt Creation.

Authors:  Senthil S Gunasekaran; Ron C Gaba
Journal:  J Clin Imaging Sci       Date:  2017-03-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.