Literature DB >> 25594117

Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States.

Youyou Xiong1, Uta Krogmann, Gediminas Mainelis, Lisa A Rodenburg, Clinton J Andrews.   

Abstract

Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should include mixed mode thermal comfort models, semi-volatile organic compounds, assessment of new chemicals, and permissible exposure levels of many known indoor VOCs and bioaerosols. Plus, the relationship between energy consumption and IAQ, and tenant education on health effects of indoor pollutants and their sources may need more attention in IAQ investigations in green buildings.

Entities:  

Keywords:  Green building; IAQ; LEED; VOC; particulate matter; residential high-rise building

Mesh:

Substances:

Year:  2015        PMID: 25594117     DOI: 10.1080/10934529.2015.981101

Source DB:  PubMed          Journal:  J Environ Sci Health A Tox Hazard Subst Environ Eng        ISSN: 1093-4529            Impact factor:   2.269


  5 in total

1.  Exposure to formaldehyde and asthma outcomes: A systematic review, meta-analysis, and economic assessment.

Authors:  Juleen Lam; Erica Koustas; Patrice Sutton; Amy M Padula; Michael D Cabana; Hanna Vesterinen; Charles Griffiths; Mark Dickie; Natalyn Daniels; Evans Whitaker; Tracey J Woodruff
Journal:  PLoS One       Date:  2021-03-31       Impact factor: 3.240

2.  Indoor air quality in green-renovated vs. non-green low-income homes of children living in a temperate region of US (Ohio).

Authors:  Kanistha C Coombs; Ginger L Chew; Christopher Schaffer; Patrick H Ryan; Cole Brokamp; Sergey A Grinshpun; Gary Adamkiewicz; Steve Chillrud; Curtis Hedman; Meryl Colton; Jamie Ross; Tiina Reponen
Journal:  Sci Total Environ       Date:  2016-03-05       Impact factor: 7.963

3.  Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US.

Authors:  Nirmala T Myers; Leonardo Calderón; Brian Pavilonis; Zuocheng Wang; Youyou Xiong; MaryAnn Sorensen-Allacci; Deborah Plotnik; Jennifer Senick; Jie Gong; Uta Krogmann; Clinton J Andrews; Gediminas Mainelis
Journal:  Indoor Air       Date:  2020-09-30       Impact factor: 5.770

Review 4.  Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure.

Authors:  Mehzabeen Mannan; Sami G Al-Ghamdi
Journal:  Int J Environ Res Public Health       Date:  2021-03-22       Impact factor: 3.390

5.  Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior.

Authors:  Allison P Patton; Leonardo Calderon; Youyou Xiong; Zuocheng Wang; Jennifer Senick; MaryAnn Sorensen Allacci; Deborah Plotnik; Richard Wener; Clinton J Andrews; Uta Krogmann; Gediminas Mainelis
Journal:  Int J Environ Res Public Health       Date:  2016-01-20       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.