Literature DB >> 25589548

Advanced digital subtraction angiography and MR fusion imaging protocol applied to accurate placement of flow diverter device.

Giuseppe Faragò1, Valentina Caldiera1, Giovanni Tempra1, Elisa Ciceri1.   

Abstract

In recent years there has been a progressive increase in interventional neuroradiology procedures, partially due to improvements in devices, but also to the simultaneous development of technologies and radiological images. Cone beam CT (Dyna-CT; Siemens) is a method recently used to obtain pseudo CT images from digital subtraction angiography (DSA) with a flat panel detector. Using dedicated software, it is then possible to merge Dyna-CT images with images from a different source. We report here the usefulness of advanced DSA techniques (Syngo-Dyna CT, three-dimensional DSA iPilot) for the treatment of an intracranial aneurysm with a flow diverter device. Merging MR and Dyna-CT images at the end of the procedure proved to be a simple and rapid additional method of verifying the success of the intervention. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

Entities:  

Keywords:  Aneurysm; Angiography; Flow Diverter; Intervention; Magnetic Resonance Angiography

Mesh:

Year:  2015        PMID: 25589548     DOI: 10.1136/neurintsurg-2014-011428.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  4 in total

1.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

2.  Treatment of Intra- and Extracranial Aneurysms Using the Flow-Redirection Endoluminal Device: Multicenter Experience and Follow-Up Results.

Authors:  F Drescher; W Weber; A Berlis; S Rohde; A Carolus; S Fischer
Journal:  AJNR Am J Neuroradiol       Date:  2016-11-03       Impact factor: 3.825

3.  Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation.

Authors:  Giuseppe Faragò; V Caldiera; C Antozzi; A Bellino; A Innocenti; E Ciceri
Journal:  Eur Radiol       Date:  2016-08-26       Impact factor: 5.315

4.  CBCT-based 3D MRA and angiographic image fusion and MRA image navigation for neuro interventions.

Authors:  Qiang Zhang; Zhiqiang Zhang; Jiakang Yang; Qi Sun; Yongchun Luo; Tonghui Shan; Hao Zhang; Jingfeng Han; Chunyang Liang; Wenlong Pan; Chuanqi Gu; Gengsheng Mao; Ruxiang Xu
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889