Skeletal troponin I cross-reactivity in different cardiac troponin I assay versions.

Heidi Hyytiä1, Taina Heikkilä2, Pirjo Hedberg3, Tarja Puolakanaho3, Kim Pettersson2.   

Abstract

OBJECTIVES: To study the skeletal troponin I (skTnI) cross-reactivity of four different commercially available antibodies in four cardiac troponin I (cTnI) research assay versions having the same epitope specificity as evidenced by peptide mapping. DESIGN AND METHODS: The four research assays all use two solid phase antibodies and one detection antibody attached to intrinsically fluorescent nanoparticles. Two alternative antibodies were used for one capture antibody and two for the detector antibody. The assays were evaluated in terms of analytical sensitivity and by determining assay cross-reactivity to skTnI. Additionally, regression analysis was performed by measuring a sample panel (n=101) with all of the four assay versions.
RESULTS: A false-positive cTnI concentration of >7000ng/L was measured with one of the assay versions, when serum was spiked with 500,000ng/L skTnI. The corresponding observed cTnI values for the other three assay versions varied from 616ng/L to 727ng/L. Out of the 101 clinical samples assayed, five showed spuriously (3- to 148-fold) elevated cTnI values with the skTnI interference prone assay setup, but not with the other assay versions. According to our investigational skTnI assay, all five samples contained measurable amounts of skTnI (range: 5500-702,000ng/L).
CONCLUSIONS: Two out of four cTnI antibodies tested cross-reacted vastly with skTnI but did not cause any notable interference unless paired together. Therefore, skTnI cross-reactivity should be carefully assessed when cTnI assay antibodies claimed to be cTnI specific are selected.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cross-reactivity; Immunoassay; Troponin I

Mesh:

Substances:

Year:  2015        PMID: 25583092     DOI: 10.1016/j.clinbiochem.2014.12.028

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  4 in total

1.  Improving the sensitivity of immunoassays by reducing non-specific binding of poly(acrylic acid) coated upconverting nanoparticles by adding free poly(acrylic acid).

Authors:  Satu Lahtinen; Annika Lyytikäinen; Nina Sirkka; Henna Päkkilä; Tero Soukka
Journal:  Mikrochim Acta       Date:  2018-03-13       Impact factor: 5.833

Review 2.  Evaluation of Molecularly Imprinted Polymers for Point-of-Care Testing for Cardiovascular Disease.

Authors:  Brian Regan; Fiona Boyle; Richard O'Kennedy; David Collins
Journal:  Sensors (Basel)       Date:  2019-08-09       Impact factor: 3.576

Review 3.  Exercise-Induced Cardiac Troponin Elevations: From Underlying Mechanisms to Clinical Relevance.

Authors:  Vincent L Aengevaeren; Aaron L Baggish; Eugene H Chung; Keith George; Øyunn Kleiven; Alma M A Mingels; Stein Ørn; Rob E Shave; Paul D Thompson; Thijs M H Eijsvogels
Journal:  Circulation       Date:  2021-12-13       Impact factor: 29.690

Review 4.  False-Positive Causes in Serum Cardiac Troponin Levels.

Authors:  Aleksey Michailovich Chaulin
Journal:  J Clin Med Res       Date:  2022-02-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.